REMOTE CONTROL OF THE VENTILATOR
Turning the unit on/off. The unit may be turned off only if it is enabled by the settings.
Reset of alarm and timer settings.
Speed selection: high-medium-low respectively.
Regeneration mode.
The fan rotation direction changes to opposite every 70 seconds. This mode enables heat recovery.
Ventilation mode.
The ventilator operates in the supply or extract mode with a set speed. The fan rotation direction depends on DIP-switch positioning (extract
mode by default).
Party mode: the timer activates operation of the unit with the high speed for a set time period, 4 hours by default. The setting may be edited
during setup of the ventilator or using the mobile application.
Night mode: the timer activates operation of the ventilator with the low speed for a set time period, 8 hours by default. The timer setting
may be changed during setup of the ventilator or using the mobile application.
The ventilator reverts to operation with a previous speed setting upon elapse of the set time period.
Press any speed key to deactivate the timer or press the timer control button once again.