GB
89
PRIOR TO INSTALLATION
Heat deflector
Install the heat deflector according to
separate instructions.
Note that Contura’s protective screen is
used instead of the heat deflector for all
Ci51 installations.
For installation in the UK and in
smoke control areas
The Contura i50 and i51, 8 kW woodburning stoves has been
recommended as suitable for use in smoke control areas. This
when burning wood logs and operated in accordance with these
instructions and when fitted with a permanent stop to prevent
closure of primary air control beyond the 52 mm² open position,
secondary air control beyond the 500 mm² open position and the
tertiary air control beyond the 215 mm² open position.
Mandatory for smoke control areas
The permanent stop must be installed if the appliance is to be
used in a smoke control area, this stop must not be removed in
smoke control areas, otherwise an offence will be committed if
the appliance is used without the permanent stop in place.