Rear connection
If connecting at the rear, we recommend using
a 45°+45° angle with a soot hatch and with the
centre 235 mm above the sleeve.
It is important that sweeping can be carried
out through convection grates or a hatch in the
surround.
Chimney
CHIMNEY/SELF-CLOSING DOOR
The insert is approved for connection to a chimney designed to
withstand flue gas temperatures of up to 350°C. The external
diameter of the connection sleeve is Ø
150
mm.
The insert requires a draft in the chimney of at least –12 Pa. The
draft is affected primarily by the length and area of the chimney
and also by how well sealed it is. The minimum recommended
chimney length is 3.5 m and a suitable cross-section area is
150-200 cm
2
(Ø140-160 mm). Carefully check that the chimney is
sealed and that there is no leakage of smoke from the soot doors
or connections.
Note that sharp bends and horizontal lengths in a flue pipe reduce
the draft in the chimney. The maximum horizontal length of flue
pipe allowed is 1 m, provided the flue pipe rises vertically for at
least 5 m. It must be possible to sweep the full length of the flue,
and the soot doors must be easily accessible.
If two fireplaces are connected to the same chimney flue, the
stove must be fitted with a self-closing door.
Summary of Contents for Contura Ci50
Page 1: ...Ci50 contura eu Installation instructions...
Page 6: ...x3 GB 86 PRIOR TO INSTALLATION...
Page 7: ...10 mm GB 87 PRIOR TO INSTALLATION...
Page 10: ...1 2 GB 90 PRIOR TO INSTALLATION Installation of metal ba e plate...
Page 11: ...1 2 3 4 5 6 7 8 GB 91 PRIOR TO INSTALLATION Removing the hearth cladding...
Page 12: ...GB 92 Option Installing Powerstone OPTION...
Page 18: ......
Page 19: ......