GB
82
CERTIFICATE
PRODUCT
Type
Wood burning insert
Trade name
Contura i50
Intended area of use
Heating of rooms in residential buildings
Fuel
Wood
MANUFACTURER
Name
NIBE AB / Contura
Address
Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
VERIFICATION
According to AVCP
System 3
European standard
EN 13229:2001/A2:2004/AC:2007
Test institute
Rein-Ruhr Feuerstätten Prüfstelle, NB 1625.
Declaration of performance according
to Regulation (EU) 305/2011
DECLARED PERFORMANCE
ESSENTIAL CHARACTERISTICS
PERFORMANCE
HARMONISED TECHNICAL
SPECIFICATION
Fire safety
Pass
Fire classification
A1
Minimum distance to flammable
materials
Rear:
150 mm (With heat shield)
Side:
700 mm
Ceiling: 550 mm (Front grate)
Ceiling: 750 mm (Top grate)
Front: 1500 mm
Floor: 0 mm
Corner: NPD
Fire hazard due to burning fuel falling out
Pass
EN 13229:2001/A2:2004/AC:2007
Cleanability
Pass
Emissions from combustion
CO:
0,08%
Surface temperatures
Pass
Temperature on the handle
NPD
Mechanical resistance
Pass
Temperature in the space for wood storage
NPD
Nominal output
8,0 kW
Efficiency
80,0%
Flue gas temperature at nominal output
278°C
Flue gas temperature in flue spigot
334°C
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Business area manager NIBE STOVES
Markaryd, December 19, 2019
No. Ci50-CPR-191219
Summary of Contents for Contura Ci50
Page 1: ...Ci50 contura eu Installation instructions...
Page 6: ...x3 GB 86 PRIOR TO INSTALLATION...
Page 7: ...10 mm GB 87 PRIOR TO INSTALLATION...
Page 10: ...1 2 GB 90 PRIOR TO INSTALLATION Installation of metal ba e plate...
Page 11: ...1 2 3 4 5 6 7 8 GB 91 PRIOR TO INSTALLATION Removing the hearth cladding...
Page 12: ...GB 92 Option Installing Powerstone OPTION...
Page 18: ......
Page 19: ......