Hot Water Storage Tank with Two Coils

BA-ST 9022/9100 - 2FE

2. DESIGN

Verti cal  storage  tanks  with  two  coils  of  BA-ST  Series  are 

pressure  equipment,  i.e.  the  pressure  within  the  storage 

tanks and coils are equivalent to the pressures in the corre-

sponding systems.

All products are ready for the installati on of a heati ng 

unit containing an electric heater with thermostat and 

thermal switch.

Informati on

Storage  tank  is  made  of  high  quality  steel  and  is  equipped 

with  two  helical  coils  that  can  simultaneously  operate  with 

two independent heat sources, e.g. a solar heati ng system, 

fi replace with water jacket or central heati ng boiler. In each 

version, the hot water tank is protected against corrosion by 

ceramic coati ng and insulated protecti ve magnesium anode. 

Thermal insulati on of the tank is a specially selected insula-

ti on that provides excellent thermal insulati on properti es of 

all  devices.  Storage  tanks  have  aestheti c  plasti c  housing,  a 

temperature indicator, inspecti on opening and connectors for 

mounti ng electric heati ng unit and connecti ng the hot water 

circulati on.

Fig. 2 

Secti on of the BA-ST 9022-9050 - 2FE storage tanks.

Fig. 3 

Side view of the BA-ST 9022-9050 - 2FE storage tanks.

1

2

3
4

5

6

7

8

9

10

11

12
13
14
15
16

15
17

15

18

19

1.  Upper insulati on of the storage tank

2.  Upper coil

3.  Protecti ve magnesium anode

4.  Enamelled tank

5.  Side insulati on of the storage tank

6.  Lower coil

7.  Lower insulati on of the storage tank 

8.  Adjustable foot

9.  Thermometer

10.  Connector pipe for mounti ng electric heati ng unit

11.  Inspecti on opening

12.  Hot water intake connector pipe

13.  Upper coil supply connector pipe

14.  Hot water circulati on connector pipe

15.  Temperature sensor cover

16.  Connecti on of return line from the upper coil

17.  Lower coil supply connector pipe

18.  Connecti on of return line from the lower coil

19.  Cold water supply connector pipe

INSTALLATION AND OPERATING MANUAL

Summary of Contents for BA-ST 9022 - 2FE

Page 1: ...Installation and Operating Manual Hot Water Storage Tank with Two Coils BA ST 9022 2FE BA ST 9030 2FE BA ST 9040 2FE BA ST 9050 2FE BA ST 9075 2FE BA ST 9100 2FE 22 02 2016 25621...

Page 2: ...product design changes and changes in the manual NIBE 2016 CONTENT 1 GENERAL 3 1 1 Introduction 3 1 2 Intended Use 3 2 DESIGN 4 3 INSTALLATION 6 3 1 Location of the Storage Tank 6 3 2 Housing Disassem...

Page 3: ...ge tank enables trouble free operation with al most any central heating system with forced circulation They are easy to install safe and comfortable to use if installed and operated in accordance with...

Page 4: ...xcellent thermal insulation properties of all devices Storage tanks have aesthetic plastic housing a temperature indicator inspection opening and connectors for mounting electric heating unit and conn...

Page 5: ...r 10 Connector pipe for mounting electric heating unit 11 Inspection opening 12 Hot water intake connector pipe 13 Upper coil supply connector pipe 14 Hot water circulation connector pipe 15 Temperatu...

Page 6: ...ions or the appropriate magnesium chain anode For the speci cation of the protective anodes available at NIBE see Section 6 Accessories and Spare Parts Amin Fig 6 Min clearance for the replacement of...

Page 7: ...e to the sewerage or drain grate Safety valve drain line should be installed with a decline in an environment free of freezing and remain open to the atmosphere The manufacturer is not responsible for...

Page 8: ...vented the storage tank is ready to use After the installation and levelling the tank follow the proce dure below for the connector pipe numbers refer to Fig 3 and Fig 5 Filling and venting the hot wa...

Page 9: ...aning of the storage tank 5 1 Inspection of the Protective Magnesium Anode Storage tanks with two coils of BA ST Series are in order to protect them against corrosion coated inside with ceramic enamel...

Page 10: ...ntervals Storage tank cleaning procedure During mechanical cleaning be careful to not damage the enamel In the case of chemical cleaning pay special attention to neutralize the chemicals used for clea...

Page 11: ...BA ST 9022 2FE ME 1500 1 5 kW 1 ME 2000 2 0 kW 1 WP 6 81 4 0 kW 1 BA ST 9030 2FE BA ST 9040 2FE BA ST 9050 2FE WP 6 8 4 5 kW 1 MEL 1030 3 0 kW 1 MEL 1060 6 0 kW 1 BA ST 9075 2FE WP 12 12 0 kW 2 MEL 2...

Page 12: ...4 9 38 8 5 8 5 Lower coil area m2 1 4 1 6 2 13 2 74 2 74 Lower coil volume l 4 2 9 38 13 16 16 Max tank operating temp C 85 Max allowable instantaneo us temp in the tank C 98 Max coil operating temp...

Page 13: ...sions F F E E D D P O N M L K J I H G D D E E F F G G H H I I J J K K L N M L N M O O P P R R W W Fig 15 Dimensions of the BA ST 9022 9050 2FE storage tanks Fig 16 Dimensions of the BA ST 9075 9100 2F...

Page 14: ...male H Return from lower coil inch Male 1 Male G Cold water input inch Male 1 Male 1 Male Dimensions BA ST 9022 2FE BA ST 9030 2FE BA ST 9040 2FE BA ST 9050 2FE BA ST 9075 2FE BA ST 9100 2FE B mm 665...

Page 15: ......

Page 16: ...ielle RD 28 Rue du Pou du Ciel 01600 Reyrieux Tel 04 74 00 92 92 Fax 04 74 00 42 00 E mail info nibe fr www nibe fr FR NIBE Energy Systems Ltd 3C Broom Business Park BridgeWay Chesterfield S41 9QG Tel...

Reviews: