Hot Water Storage Tank with Two Coils

BA-ST 9022/9100 - 2FE

1. GENERAL

1.1 Introducti on

Thank you for your confi dence and choice of equipment by 

NIBE. To fully benefi t from the advantages of this product, ple-

ase read this Manual before using it, and in parti cular chap-

ters relati ng to the applicati on, installati on and maintenance, 

and warranty. Please keep this Manual in a safe place for fu-

ture reference.

1.2 Intended Use

NIBE hot water storage tanks with two coils are only intended 

for heati ng up, storage and supply the domesti c hot water.

Verti cal storage tanks with two coils of BA-ST Series are de-

signed to heat and store hot water in systems with two heat 

sources, e.g. solar heati ng system with a central heati ng boiler 

or central heati ng boiler with a fi replace and with a water jac-

ket. The storage tank enables trouble-free operati on with al-

most any central heati ng system with forced circulati on. They 

are  easy  to  install,  safe  and  comfortable  to  use,  if  installed 

and operated in accordance with the advices contained in this 

Manual. The heated water can be supplied to several intake 

points at various, mutually distant locati ons, such as, a bath-

tub, washbasin, sink, etc.

Storage tank with two coils are designed to heat up 

and  supply  water  for  domesti c  purposes.  Any  inap-

propriate use, not in compliance with its intended use 

is  not  permitt ed.  Neither  manufacturer  nor  supplier 

shall be responsible for damages resulti ng from this.

CAUTION

Fig. 1 

BA-ST hot water storage tank

.

INSTALLATION AND OPERATING MANUAL

Secti ons of the Manual relati ng to the installati on, in-

specti on and maintenance are intended for the quali-

fi ed installer.

CAUTION

The manufacturer shall not be held liable for any da-

mages caused by failure to comply with the recommen-

dati ons and observati ons contained in this Manual.

CAUTION

Summary of Contents for BA-ST 9022 - 2FE

Page 1: ...Installation and Operating Manual Hot Water Storage Tank with Two Coils BA ST 9022 2FE BA ST 9030 2FE BA ST 9040 2FE BA ST 9050 2FE BA ST 9075 2FE BA ST 9100 2FE 22 02 2016 25621...

Page 2: ...product design changes and changes in the manual NIBE 2016 CONTENT 1 GENERAL 3 1 1 Introduction 3 1 2 Intended Use 3 2 DESIGN 4 3 INSTALLATION 6 3 1 Location of the Storage Tank 6 3 2 Housing Disassem...

Page 3: ...ge tank enables trouble free operation with al most any central heating system with forced circulation They are easy to install safe and comfortable to use if installed and operated in accordance with...

Page 4: ...xcellent thermal insulation properties of all devices Storage tanks have aesthetic plastic housing a temperature indicator inspection opening and connectors for mounting electric heating unit and conn...

Page 5: ...r 10 Connector pipe for mounting electric heating unit 11 Inspection opening 12 Hot water intake connector pipe 13 Upper coil supply connector pipe 14 Hot water circulation connector pipe 15 Temperatu...

Page 6: ...ions or the appropriate magnesium chain anode For the speci cation of the protective anodes available at NIBE see Section 6 Accessories and Spare Parts Amin Fig 6 Min clearance for the replacement of...

Page 7: ...e to the sewerage or drain grate Safety valve drain line should be installed with a decline in an environment free of freezing and remain open to the atmosphere The manufacturer is not responsible for...

Page 8: ...vented the storage tank is ready to use After the installation and levelling the tank follow the proce dure below for the connector pipe numbers refer to Fig 3 and Fig 5 Filling and venting the hot wa...

Page 9: ...aning of the storage tank 5 1 Inspection of the Protective Magnesium Anode Storage tanks with two coils of BA ST Series are in order to protect them against corrosion coated inside with ceramic enamel...

Page 10: ...ntervals Storage tank cleaning procedure During mechanical cleaning be careful to not damage the enamel In the case of chemical cleaning pay special attention to neutralize the chemicals used for clea...

Page 11: ...BA ST 9022 2FE ME 1500 1 5 kW 1 ME 2000 2 0 kW 1 WP 6 81 4 0 kW 1 BA ST 9030 2FE BA ST 9040 2FE BA ST 9050 2FE WP 6 8 4 5 kW 1 MEL 1030 3 0 kW 1 MEL 1060 6 0 kW 1 BA ST 9075 2FE WP 12 12 0 kW 2 MEL 2...

Page 12: ...4 9 38 8 5 8 5 Lower coil area m2 1 4 1 6 2 13 2 74 2 74 Lower coil volume l 4 2 9 38 13 16 16 Max tank operating temp C 85 Max allowable instantaneo us temp in the tank C 98 Max coil operating temp...

Page 13: ...sions F F E E D D P O N M L K J I H G D D E E F F G G H H I I J J K K L N M L N M O O P P R R W W Fig 15 Dimensions of the BA ST 9022 9050 2FE storage tanks Fig 16 Dimensions of the BA ST 9075 9100 2F...

Page 14: ...male H Return from lower coil inch Male 1 Male G Cold water input inch Male 1 Male 1 Male Dimensions BA ST 9022 2FE BA ST 9030 2FE BA ST 9040 2FE BA ST 9050 2FE BA ST 9075 2FE BA ST 9100 2FE B mm 665...

Page 15: ......

Page 16: ...ielle RD 28 Rue du Pou du Ciel 01600 Reyrieux Tel 04 74 00 92 92 Fax 04 74 00 42 00 E mail info nibe fr www nibe fr FR NIBE Energy Systems Ltd 3C Broom Business Park BridgeWay Chesterfield S41 9QG Tel...

Reviews: