20
NIBE
TM
AP-AW10
We reserve the right to make technical changes
83050406cUK – Translation of the operating manual
attentIon
Ensure clockwise rotary field of the load power
supply (compressor).
–
An incorrect rotary field of the compressor
during operation can cause serious, irreparable
damage to the compressor.
attentIon
make sure to equip the power supply of the heat
pump with a 3-pole automatic cut-out with at
least 3mm contact gap.
Note the level of the release current.
overview “Technical data / scope of delivery”,
“Electric” section.
E
D
C
B
www.alpha-innotec.de
D - 95359 Kasendorf
Industriestraße 3
Alpha-InnoTec GmbH
1
1
Ers. d.
Ers. f.
Benennung
Durchflusssensor VFS5-100
603772
-
Zust.
Änderungstext
Datum
9.2.2009
HS
Von
Blatt
von
Werkstoff
Gewicht
-
Maßstab
1:2
Det. Maßstab
Datum
Name
Erstellt
Gepr.
Norm.
9.2.2009
Stenglein
toleranz
Allgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.
---
1
2
3
4
Schutzvermerk nach DIN 34 beachten
Blattformat: A4 hoch
CautIon.
The sensor cable for heat quantity recording
may not be shortened!
notICe.
The control element of the heat and heat pump
regulator can be a connection with a computer
or network using an network cable designed for
such pruposes, thus allowing the heating and
heat pump regulator to be controlled remotely.
If such a connection is desired, install a screened
network cable (category 6, with RJ-45 plug)
through the unit when installing the connections
and run it through the front facade of the unit,
parallel to the already-present heating and heat
pump regulator control cable.
close electrical switch cabinet of unit.
Insert the power line and the sensor wires into the
unit through the rubber sockets on the back of the
unit…
1 Rubber sockets
for positioning of the rubber sockets for
inserting the wires, see “dimensional drawing”
for the respective model.
The wires inside the unit are guided in a closed wire
duct to the switch cabinet…
1 Wire duct in unit
2 cable glands switch cabinet
3 connections for power
and control wires
4 connections for regulator board
Install electric connections according to the
terminal diagram that applies to your model…
Terminal diagram for respective model.