AMS 10

Table of Contents |

Summary of Contents for AMS 10

Page 1: ...User manual LEK L E K LEK LE K UN AMS 10 AMS 10 6 10 8 10 12 10 16 Air water heat pump UHB EN 1746 1 331961 ...

Page 2: ......

Page 3: ... serial number 8 AMS 10 An excellent choice 10 2 The heat pump the heart of the house 10 Heat pump function 12 Contact with AMS 10 13 Maintenance of AMS 10 18 3 Disturbances in comfort 18 Troubleshooting 19 4 Technical data 20 5 Glossary 24 Item register 27 Contact information 3 AMS 10 Table of Contents ...

Page 4: ...on date Installer Always specify the service code and serial number Certification that the installation is carried out according to instructions in NIBE s installer manual and applicable regulations _________________________ Signed __________________ Date AMS 10 Chapter 1 Important information 4 ...

Page 5: ...d similar environ ments Children must be instructed supervised to ensure that they do not play with the appliance Do not allow children to clean or maintain the appli ance unsupervised This is an original manual It may not be translated without the approval of NIBE Rights to make any design or technical modifications are reserved NIBE 2017 NOTE AMS 10 must be installed via an isolator switch with ...

Page 6: ...ntaining your installation TIP This symbol indicates tips on how to facilitate using the product Marking The CE mark is obligatory for most products sold in the EU regardless of where they are made CE Classification of enclosure of electro technical equipment IP21 Danger to person or machine Read the User Manual AMS 10 Chapter 1 Important information 6 ...

Page 7: ...Service code and serial number You can find the service code and the serial number PF3 on the right hand side of AMS 10 PF3 LEK PF3 7 AMS 10 Chapter 1 Important information ...

Page 8: ...te which utilises the outdoor air as its energy source AMS 10 together with a SPLIT box HBS 05 is intended for connection to water borne heating systems and can both heat hot water effectively at high outdoor temperatures and provide high capacity to the heating sys tem at low outdoor temperatures Excellent properties for AMS 10 Efficient twin rotary compressor Efficient twin rotary compressor tha...

Page 9: ...ice life The material has been chosen for a long service life and good durability Many possibilities AMS 10 together with SPLIT box HBS 05 is intended to be combined with NIBE indoor module VVM NIBE control module SMO There is a wide range of system solutions and accessories for all of our indoor modules and control modules Silent operation AMS 10 has a silent operation function that allows schedu...

Page 10: ...eating medium Värmebärare Köldmedium Köldbärare Värmekälla Förångare Kondensor 100 C 0 C 3 C 2 C 50 C 40 C Expansionsventil Kompressor A D F H B C E G Brine Refrigerant Evaporator Condenser Expansion valve Compressor Heat source 1 2 3 The temperatures are only examples and may vary between different installations and time of year AMS 10 Chapter 2 The heat pump the heart of the house 10 ...

Page 11: ...boil C The gas that is produced during boiling is routed into an electrically powered compressor When the gas is compressed the pressure increases and the gas s temperature increases considerably from 5 C to approx 80 C D From the compressor gas is forced into a heat exchanger condenser where it releases heat energy to the heating system in the house whereupon the gas is cooled and condenses to a ...

Page 12: ... HBS 05 and your indoor module VVM or control module SMO See relevant manual for more information During installation the installation engineer adjusts the necessary settings for the heat pump in the indoor module or control module so that the heat pump works optimally in your system AMS 10 Chapter 2 The heat pump the heart of the house 12 ...

Page 13: ...e guarantee Checking grilles and bottom panel on AMS 10 Check that the inlet grille is not clogged by leaves snow or anything else regularly throughout the year You should be vigilant during windy conditions and or in the event of snow as the grilles can become blocked Also check that the drain holes in the bottom panel three are free from dirt and leaves Regularly check that condensation is route...

Page 14: ...ee of snow and ice LEK LEK LEK LEK Prevent snow from building up and covering the grilles and drain holes on AMS 10 LEK LEK Keep free of snow and or ice AMS 10 Chapter 2 The heat pump the heart of the house 14 ...

Page 15: ...on are for example indoor tem perature hot water consumption the insulation level of the house and whether the house has many large window surfaces The position of the house e g wind exposure is also an affecting factor Also remember Open the thermostat valves completely except in the rooms that are to be kept cooler for various reasons e g bedrooms The thermostats slow the flow in the heating sys...

Page 16: ...6 h week 50 1 40 Radio stereo Operation 3 h day 120 2 100 Computer incl screen Operation 3 h day standby 21 h day 175 60 Bulb Operation 8 h day 58 20 Spot light Halogen Operation 8 h day 165 100 Cooling Operation 24 h day 380 120 Freezer Operation 24 h day 365 1500 Stove hob Operation 40 min day 310 3000 Stove oven Operation 2 h week 730 2000 Dishwasher cold water connection Opera tion 1 time day ...

Page 17: ...y once a month This will indicate any changes in power consumption Newly built houses usually have twin energy meters use the difference to calculate your domestic electricity New builds Newly built houses undergo a drying out process for a year The house can then consume significantly more energy than it would thereafter After 1 2 years the heating curve should be adjusted again as well as the of...

Page 18: ... the indoor module control module VVM SMO Basic actions Make sure that the air flow to AMS 10 is not blocked by foreign objects Check that AMS 10 does not have any external damage Ice build up in the fan grille and or fan cone on AMS 10 Contact your installer Large amount of water below AMS 10 Check that the water drainage via the condensation pipe KVR 10 is working AMS 10 Chapter 3 Disturbances i...

Page 19: ...4 Technical data Detailed technical specifications for this product can be found in the in stallation manual www nibe eu 19 AMS 10 Chapter 4 Technical data ...

Page 20: ...ual to the building s output requirement This means that the heat pump covers the whole building s output requirement down to this temperature Charge coil A charge coil heats the domestic hot water tap water in the water heater with heating water heating medium from AMS 10 Charge pump See Circulation pump Circulation pump Pump that circulates liquid in a pipe system Climate system Climate systems ...

Page 21: ...etimes be noticed in the form of a disturbance in comfort In most cases the heat pump notes malfunctions and indicates this with alarms in the display Domestic hot water The water one showers in for example Double jacketed tank A heater with domestic hot water tap water is surrounded by an outer vessel with boiler water to the house radiators elements The heat pump heats the boiler water which in ...

Page 22: ...exchangers are evaporators and condensers Heat factor Measurement of how much heat energy the heat pump gives off in relation to the electric energy it needs to operate Another term for this is COP Heating medium Hot liquid usually normal water which is sent from the heat pump to the house climate system and makes the accommodation warm The heating medium also heats the hot water Heating medium si...

Page 23: ...t pump after releasing the heat energy to the radiators heating coils Safety valve A valve that opens and releases a small amount of liquid if the pressure is too high Shuttle valve A valve that can send liquid in two directions A shuttle valve that enables liquid to be sent to the climate system when the heat pump produces heating for the house and to the hot water heater when the heat pump produ...

Page 24: ...on 5 Serial number 7 Installation data 4 L Large amount of water below AMS 10 18 M Maintenance of AMS 10 13 Regular checks 13 Saving tips 15 Silent mode 15 P Power consumption 15 R Regular checks 13 S Safety information 5 Saving tips 15 Power consumption 15 Serial number 7 Silent mode 15 T Technical data 19 The heat pump the heart of the house 10 Contact with AMS 10 12 Heat pump function 10 Mainte...

Page 25: ......

Page 26: ......

Page 27: ...one industrielle RD 28 Rue du Pou du Ciel 01600 Reyrieux Tel 04 74 00 92 92 E mail info nibe fr www nibe fr FR NIBE Energy Systems Ltd 3C Broom Business Park Bridge Way S419QG Chesterfield Tel 44 0 845 095 1200 E mail info nibe co uk www nibe co uk GB NIBE Energietechniek B V Postbus 634 NL 4900 AP Oosterhout Tel 0168 477722 E mail info nibenl nl www nibenl nl NL ABK AS Brobekkveien 80 0582 Oslo P...

Page 28: ...WS name Gemensamt WS version a423 WS release date 2017 09 25 11 38 Publish date 2017 11 27 07 59 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu 331961 ...

Reviews: