E5
RAT (Room Air
Temperature) sensor fault.
Fan is stopped and flap is
closed.
The system restarts as soon
as the sensor is repaired.
Reconnect or replace the sensor.
Check that the fan motor is properly
connected to the PCB as shown in the
electrical wiring diagram.
Check that the fan motor is not locked.
E6
Fan motor error.
Fan is stopped and flap is
closed.
The system restarts
automatically after some
seconds.
Check that the fan motor is not damaged
and, if necessary, replace it.
E8
Combination between
outdoor unit and indoor
unit is not allowed.
Fan is stopped and flap is
closed.
Check the catalog for the allowed
combinations. Choose a correct indoor-
outdoor unit combination.