Components operation
Indoor Fan
When unit is switched on, indoor fan runs at the speed selected on the remote controller.
Auto fan speed
If Auto Fan speed is selected, the fan speed will be managed according to the graph below:
where TL is the thermal load of the room calculated by the controller.
Cold Draft protection
When unit is in heating mode, fan speed could be limited or stopped to prevent cold air drafts from the
heat exchanger when heat exchanger is not warm enough.
In this case, fan speed is managed accorging to the graph below:
(*): Values can vary based on “dynamic cold draft” algorithm.
MIN
Fan speed
31°C
Remote controller set
0
ICT (*)
37°C
MIN
Fan speed
0
LOW
HIGH
TL
MAX