44
45
Controller “VERSION” report explanation
SMS format
Explanation
Ver: version number
NIBE AG-BU10 firmware version
Pump: type,ON/OFF
Heat pump status: type and ON/OFF/NO POWER
Power: ON/OFF(x.xx V)
Voltage 5 V input and battery voltage
(3.50 V – 4.20 V)
Room: xx °C
Room temperature in Celsius degrees
GSM: sq, cell
GSM signal strength (0 – 100 %) and GSM area info
(1-local network, 5-roaming)
Life: mm.dd
Controller run time: months, days
Owner: number
Owner mobile phone number
”SETUP” report explanation
SMS format
Explanation
Owner: number / All
Owner number or All if not defined
Users: number1, number2 / All
User1 and User2 number or All if not defined
Heat pump: model name
NIBE model 1; model 2:
Param: x1,x2,x3,x4
Parameters: 971 (low temperature.),
972 (no power), 973 (service), 974 (high temperature.)
NIBE AG-BU10 command sheets
Heat pump ON/OFF
Restart and Owner number entry
Command SMS
Heat pump function
ON
Heat pump ON
OFF
Heat pump OFF
Command SMS
Controller function
90
Setup reset (Owner deleted)
and controller restart
93
First time Owner number entry
Commands
Command SMS
Heat pump function
AUTO
AUTO (+20 °C, fan: NORM)
DRY
DRY (+20 °C, fan: AUTO)
COOL
COOL (+20 °C, fan: NORM)
HEAT
HEAT (+20 °C, fan: NORM)
Heat pump model setup
951
952
NIBE other
NIBE WT10
33 kHz
38 kHz
Command SMS
NIBE model
Frequency used