NI ELVIS RIO User Manual Download Page 7

Figure 7. Reset Button Behavior

Press and hold RESET button for 

 5 s

Press and hold RESET button for 

<

 5 s

Run Mode

Safe Mode

Press and hold RESET button for 

<

 5 s

Press and hold RESET button for 

 5 s

Press and hold

RESET button for 

 5 s 

Press and hold

RESET button for < 5 s 

• Console Out enabled
• Network settings reset
• RT Startup App disabled
• FPGA Startup App disabled

• Console Out enabled
• RT Startup App disabled
• FPGA Startup App disabled

Safe Mode

When the NI ELVIS RIO CM is in safe mode, you can communicate with it by using the
UART lines on MXP connector A. You require the following items to communicate with the
NI ELVIS RIO CM device over UART:

USB-to-TTL serial UART converter cable (for example, part number TTL-232RG-
VSW3V3-WE from FTD Chip)

You must configure your serial-port terminal program with the following settings:

115,200 bits per second

Eight data bits

No parity

One stop bit

No flow control

User Button

The User Button produces a logic TRUE when depressed and a logic FALSE when not
depressed. The User Button is not debounced in hardware.

LED Indications

Power LED

The Power LED is lit while the NI ELVIS RIO CM is powered on. This LED indicates that the
power supply connected to the device is adequate.

Status LED

The Status LED is off during normal operation. The NI ELVIS RIO CM runs a power-on self
test (POST) when you apply power to the device. During the POST, the Power and Status
LEDs turn on. When the Status LED turns off, the POST is complete. The NI ELVIS RIO CM

NI ELVIS RIO CM User Manual

  | 

© National Instruments

  | 

7

Summary of Contents for ELVIS RIO

Page 1: ...a USB connection Figure 1 NI ELVIS RIO CM Features 1 2 6 5 4 8 7 11 10 12 3 9 13 1 Power LED 2 Status LED 3 LED0 4 LED1 5 LED2 6 LED3 7 Button0 User Button 8 Reset Button 9 USB Host Port 10 Workstati...

Page 2: ...Button0 Watchdog Status LED MXP Connector Pinout AO0 AO1 AGND DGND UART RX DGND UART TX DGND DIO11 ENC A DGND DIO12 ENC B DGND DIO13 DGND DGND DIO14 I2C SCL DIO15 I2C SDA 5V AI1 AI3 AI2 DIO1 DIO2 DIO3...

Page 3: ...RT lines are electrically identical to DIO lines DGND Reference for digital signals 5 V and 3 3 V Note MXP connectors A and B have identical sets of signals and are distinguished in software by the co...

Page 4: ...controlled by a serial communication bus from the FPGA MXP connectors A and B share this bus and therefore all channels must share the same update rate The following figure shows the AO topology of t...

Page 5: ...n in the following figure Figure 6 DIO Lines with 2 2 k Pull up Resistors to 3 3 V 2 2 k FPGA Bus Switch DIO SCL SDA 3 3 V You can program all MXP DIO lines individually as inputs or outputs Secondary...

Page 6: ...ports the following devices Web cameras that conform to the USB Video Device Class UVC protocol Machine vision cameras that conform to the USB3 Vision standard and are backward compatible with the USB...

Page 7: ...T converter cable for example part number TTL 232RG VSW3V3 WE from FTD Chip You must configure your serial port terminal program with the following settings 115 200 bits per second Eight data bits No...

Page 8: ...n the device runs out of memory Review your LabVIEW Real Time VI and check the memory usage Modify the VI as necessary to solve the memory usage issue Continuously flashing or solid The device has det...

Page 9: ...ndividual users in the EU The NI ELVIS RIO CM is warranted against defects in materials and workmanship for a period of three years from the date of shipment as evidenced by receipts or other document...

Page 10: ...MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information...

Reviews: