Hunan Next Generation Instrumental T&C Tech. Co., Ltd.
NGI
l
NGI
N36100 Series
Wide Range High Voltage Programmable DC Power Supply
22
Figure 19 V/I Setting
Table 12
7.3 SEQ Edit
SEQ Edit allows users to set parameters such as file number, total steps, cycle
times,etc.
N36100 series supports complex waveform output, with up to 10 sequence files and
Max. 200 steps in total.
Methods to enter
SEQ Edit
:
Method 1: Press
Shift
button first on the front panel and then press
SEQ
button.
Method 2: Press
Menu
button→ Select
SEQ Edit
by rotating
→ Press
Enter
button.
Figure 20 SEQ Edit
Number
Description
1
Readback of output voltage
2
Setting of output voltage
3
Readback of output power
4
Readback of output current
5
Setting of output current
6
Present output status
Note: To exit from
V/I
mode, please press
Menu
button or the function button
required.