BioAxs 9750™ Installation & Operations Manual. Version 1.9
Copyright
2005 NextgenID, Inc. All Rights Reserved
33
Power (J13)
Panel Video (J12)
The output for all connected video sources is provided by the connections on the J12
Terminal. Connect the coaxial video cable run from the DCM to the J12 terminals labeled
PANEL (VID +, GND -)
Panel Video Out (J12)
Relay Output Points
Door Latch (J6 & OPT1)
The door latch mechanism (Magnetic Lock / Electric Door Strike) connections are
made on terminal J6. (POW, NC, NO, COM, GND).
Door Latch (J6)
Door
Latch
Power
Depending on the type and manufacturer of your door latch hardware, your latch
mechanism may require either 12VDC or 24VDC. Configure the DCB to deliver
power to the latch mechanism as follows:
12V Door Latch Mechanism
Using a small section of cable, jumper from the J6
POW
terminal to the J6 COM
terminal.
24V Door Latch Mechanism
Using a small section of cable, jumper from the J13
24V
terminal to the J6
COM
(Common) terminal.