SETTING THE CONTACT FOR LIMIT SWITCHES
Default: 2 NO contacts
This procedure is used to set the type of contacts of limit switches.
PROCEDURE
STEP 1
With a paper clip makes a long press of the “hidden” button.
The LED turns on light blue/pink cyclically.
Release the key when the led is light blue.
STEP 2
Press the button 1 on the receiver for a short time and count the number of Flashes emitted by the LED:
FLASHES
NUMBER
FUNCTION
1
No limit switches
2
n°2 NC contacts
3
n°2 NO contacts (default)
4
n°1 NC contact
5
n°1 NO contact
6
n°1 contact 12/24Vdc
STEP 3
Press the button for a short time during the Flash that corresponds to the
function desired to end the count.
The led turns off
ACTION:
Short press of button 1
LED:
Count the number of Flashes
ACTION:
Short press of button 1
LED:
Turns off
18