IMPORTANT NOTICE:
DO NOT return to place of purchase !!!
Please contact Customer Service hotline at 800-913-8999 for help
LOCATION HEATER FOR USE
BE CAREFUL
: When certain materials or items are left under this heater, while in use, they will be subject
to radiant heat and could be seriously damaged.
●
The unit is designed for heating outdoor patios, decks, spas, pool and working areas.
●
Always ensure that adequate fresh air ventilation is provided. Follow the spacing tolerances in Figure 1.
●
The minimum clearances to combustible construction shown in Figure 1 must be maintained at all times
●
The installation must conform to local codes or in the absence of local codes with the standard for the
storage and handling of liquid petroleum gases:
In the US use : ANSI/NFPA58 on National Fuel Gas Code ANSI Z223-1998
In Canada use: National Standards of Canada. CAN/CGA B149.1 & 2-M86
●
The heater must be placed on level firm ground.
●
Never operate in an explosive atmosphere. Keep away from areas where gasoline or other flammable
liquids or vapors are stored or used.
Figure 1.
CELING/OVERHANG
CAUTION
Page 10
During strong and windy weather, turn off the
heater and the gas cylinder valve. Remove
the heater reflector hood then move the heater
to a sheltered location. Cautions do not move
heater while it is still hot.
W
ALL
24"
18"