L.P. TANK REQUIREMENT
Only gas cylinders with a "POL" low pressure connection are
to be used with this BBQ. Cylinder size of 9 kg is
recommended for use with this BBQ. Suitable regulators
must have an outlet pressure of 2.75 kPa. You must have the
proper regulator and cylinder in order for the BBQ to operate
safely and efficiently. Only a 100% propane (LPG) refillable
gas cylinder currently certified to Australian Standard
AS 2030.1:2009 is to be used. Do not use disposable gas
cylinders.
PLEASE NOTE THE HOSE AND REGULATOR SUPPLIED
WITH THIS BBQ ARE OF AN APPROVED TYPE AND ARE
SPECIFICALLY DESIGNED FOR USE WITH YOUR BBQ.
L.P. GAS HOOK-UP
Ensure that the regulator hose does not come into contact
with the firebox.
CONNECTION
This barbeque is equipped for use with a 9 kg LP gas
cylinder (gas cylinder not supplied). A gas pressure
regulator/hose assembly is supplied and factory fitted to the
barbeque.
Any brand of 9 kg LP gas fuel tank is acceptable for use with
the barbeque, provided that it is compatible with the
barbeque’s
retention means.
It is also design-certified by AGA International for local LP
gas supply.
To connect the L.P. gas supply cylinder, please follow the
steps below:
1.
Make sure cylinder valve is in its fully OFF position (turn
clockwise to stop).
2.
Check that the 9 kg LP gas cylinder valve has the proper
POL thread female.
3.
Make sure all burner valves are in their OFF position.
4.
Inspect valve connections, port, and regulator assembly.
Look for any damage or debris. Remove any debris.
Inspect hose for damage. Never attempt to use
damaged or obstructed equipment. See your local L.P.
gas dealer for repair.
5.
When connecting regulator assembly to the cylinder
valve, hand tighten the fitting anticlockwise to a
complete stop. Do not use a spanner to tighten. Use of
a spanner may damage the thread and result in a
hazardous condition.
6.
Open the cylinder valve fully (counterclockwise). Apply
a soap solution with a clean brush to all gas
connections. See below diagram. If growing bubbles
appear in the solution the connections are not properly
sealed. Check each fitting and tighten or repair as
necessary.
7.
If you have a gas connection leak you cannot resolve,
turn gas OFF at the gas cylinder, disconnect fuel line
from your barbeque and contact your Barbeques
Galore customer service department at 1800 978 555
for after sales service and support.
8.
Also apply soapy solution to the gas cylinder seams. If
growing bubbles appear, shut gas cylinder OFF and do
not use or move it! Contact an LP gas supplier or your
fire department for assistance.
To disconnect L.P. gas cylinder:
1.
Turn the burner valves off.
2.
Turn the gas cylinder valve OFF fully (turn clockwise to
stop).
3.
Detach the regulator assembly from the gas cylinder
valve by turning the fitting clockwise.
Installer Final Check List
USER, PLEASE RETAIN THIS MANUAL FOR FUTURE
REFERENCE.
PROPANE CYLINDER CAUTIONS
a)
Do Not store a spare LP-gas cylinder under or near
this appliance.
b)
NEVER fill the cylinder beyond 80 percent capacity.
c)
If the information in above is not followed exactly, a
fire or explosion causing death or serious injury
may occur.
✓
Minimum clearance from sides and back of unit to
combustible construction, 91.44 cm / 36 in. from
sides and 91.44 cm / 36 in. from back
✓
All internal packaging removed.
✓
Knobs turn freely.
✓
Burners are tight and sitting properly on orifices.
✓
Pressure regulator connected and set. Gas
connected to barbeque using hose & regulator
assembly provided.
✓
Unit tested and free of leaks.
✓
User informed of gas supply shut off valve location
Gas Hook-Up
8
Summary of Contents for 720-0786D