NEXPEED NBG440 User’s Manual
NexComm Systems, Inc. 65 PAGE
1 default local s0 s1 lan mx0
NBG440_CO(conf)#
Step2:
Configuring the VLAN for management.
NBG440_CO(conf)# qvlan pvid 2047 1 local
NBG440_CO(conf)# qvlan add 2047 local lan s0
Step3:
Configuring 3 VLANs.
NBG440_CO(conf)# qvlan add 100 lan s0
NBG440_CO(conf)# qvlan add 110 lan s0
NBG440_CO(conf)# qvlan add 120 lan s0
Step4:
Remove the lan an s0 from the
default
vlan.
NBG440_CO(conf)# qvlan del 1 lan s0
Step5:
Set the lan and s0 as the trunk port.
NBG440_CO(conf)# qvlan trunk enable lan s0
Step6:
Enable VLAN feature.
NBG440_CO(conf)# qvlan enable
Step7:
Save your changes.
NBG440_CO(conf)# write config
Step8:
Verifying your VLAN configuration.
NBG440_CO(conf)# sh qv
-------------------------------------------------------------------------
VLAN and QoS (802.1q & 802.1p) : enabled
port pvid/pri trunk mapping-info
-------------------------------------------------------------------------
local 2047/1 no
s0 1/1 yes
s1 1/1 no