EDH0199En2041 — 12/18
12
MFA Series Miniature Linear Stages
6.0 —
Connection to Non-Newport Electronics
6.1
MFA-PPD & MFA-CC Connections
WARNING
Newport is not responsible for malfunction or damage of MFA stages
when used with non-Newport controllers.
WARNING
Newport guarantees “
” compliance of MFA stages only if used with
Newport cables and controllers.
It is the customer’s responsibility to modify the cable and take care of
sensor signal connections, when using the stage with non-Newport
controllers.
End-of-Runs and Mechanical Zero are open collector type with a 5.6 V
protective Zener diode.
Reserved
(EEPROM Enable):
I
in
max.: 10 mA
V max.: 30 V
NEWPORT STAGE
SUB-D25M CONNECTOR
+5 V
R,
Pull-Up Resistor
End-of-Run:
I
in
max.: 16 mA
V max.: 5.6 V
NEWPORT STAGE
For connection to non-Newport electronics,
pin #17 and #18 End-of-Runs must be
connected to +5 V with a pull-up resistor. For
some non-Newport controllers, the +5 V
output signal may be pulled up internally.
+5 V
R,
Pull-Up Resistor
Pin #17
Pin #18
Pin #13
5.6 V
To enable End-of-Run, when a MFA stage is
used with non-Newport controllers using the
Sub-D25M connector provided, pin #13 must
be connected to +5 V with a pull-up resistor
(ex: 4.99 k
Ω
).