7
EDH0199En2041 — 12/18
MFA Series Miniature Linear Stages
Command Signals for the DC-Motor
In the above drawings, + Motor signal is referred to – Motor signal.
➀
When the stage moves in + Direction, the + Motor voltage is higher than
– Motor voltage.
➁
When the stage moves in – Direction, the + Motor voltage is lower than
– Motor voltage.
4.3
Sensor Position
End-of-Run are 5 V open collector type.
CAUTION
“End-of-Run” are active signals and should not be connected to any other
source.
Dir
+V
+ Motor
– Motor
–V
MOTION
Dir
MOTION
Direction –
– EOR Limit
Travel Range
+ EOR Limit
Home Position
Direction –
MOTION
Dir