background image

Start Up Guide 

2.2.1 

Understanding the Main Screen 

 

The main screen is displayed after startup. The middle portion of the main 
screen is a real-time display of power measured in last used units, and the 
lower half of the main screen is a row of four labels for actions that the keys 
below them will activate.  The top of this screen has the channel settings for 
the focus channel and a smaller reading for the non-focus channel (B in the 
figure). Note that the screen will display “Saturated” message either when the 
amount of power surpasses the detector saturation specification, or when the 
detector spot size and/or detector saturation specifications are missing in the 
calibration module. 

When an annunciator label is visible, its function is enabled. If the 
annunciator appears on the display as an unlabeled key, the function it 
represents is currently disabled. Annunciators loosely correspond to keypad 
keys, which are used either alone or in combination with the navigation and 
selection keys to control annunciator functions.  

2.3 

  Rear Panel Layout 

2.3.1 

Elements That Vary by Model (on back panel) 

Single-channel power meters have the processing electronics installed on 
CH A, while dual-channel power meters have both CH A and CH B installed. 

Input Connectors 

The input connectors are on the rear panel. 1936-R and 2936-R power meter 
models support input from external detectors through DB15 detector 
connectors. Input channels on dual-channel power meters are labeled “CH A” 
and “CH B”.  

A Trigger input offers the possibility of synchronizing the power meter 
measurements with external events.  

Output Connectors 

Power meters in the 1936-R/2936-R series support one analog output for each 
channel.  Analog output enables direct monitoring of a detector through an 
oscilloscope or voltmeter. 

On the rear panel there are also trigger outputs, one for each channel. The 
user can use these outputs to synchronize external equipment with events 
related to the power meter measurements. 

2.3.2 Panel 

Layout 

The rear panel is a brushed aluminum plate with input and output connectors 
for the following cable types: 

 

15-Pin D-Sub Optical Detector Input, Channel A (1936-R/2936-R) 

 

BNC Analog Output, Channel A (1936-R/2936-R) 

 

BNC Trigger Output, Channel A (1936-R/2936-R) 

 

15-Pin D-Sub Optical Detector Input, Channel B (2936-R) 

Summary of Contents for 1936-R series

Page 1: ...Single and Dual Channel Optical Meters Start Up Guide Model 1936 R 2936 R Series...

Page 2: ......

Page 3: ...formation regarding the use and operation of the power meter is included in the complete User s Manual The complete User s Manual in Adobe PDF format and the instrument software drivers are included o...

Page 4: ...This page intentionally left blank...

Page 5: ...tion has the potential to cause damage to property or equipment ELECTRICAL SHOCK Hazard arising from dangerous voltage Any mishandling could result in irreparable damage to the equipment and personal...

Page 6: ...Warning Label If this equipment is used in a manner not specified in this manual the protection provided by this equipment may be impaired To prevent damage to equipment when replacing fuses locate an...

Page 7: ...rm the shipping company and Newport Corporation immediately WARNING Do not attempt to operate this equipment if there is evidence of shipping damage or you suspect the unit is damaged Damaged equipmen...

Page 8: ...h the rear panel input power connector that provides in line transient protection and RF filtering The input power connector contains the fuses and the switch to select series or parallel connection o...

Page 9: ...eing used for measurements 2 2 Front Panel Keys The front panel keys are organized in three groups see Figure 2 Navigation Keys Reconfigurable also called Soft Keys Escape ESC Key Besides these keys t...

Page 10: ...t 2 3 1 Elements That Vary by Model on back panel Single channel power meters have the processing electronics installed on CH A while dual channel power meters have both CH A and CH B installed Input...

Page 11: ...ar metal shell connector Markings on the rear panel identify electrical requirements for the Optical Power Meter and potential hazards associated with using it NOTE For the listed optional connectors...

Page 12: ...36 R Series 3 Using a small screwdriver insert and press down into the notch at the top of the power entry module to pry the door open 4 Carefully remove the voltage selector drum 5 Rotate the voltage...

Page 13: ...t you to restart once the upgrade is successful Restart the power meter by turning it OFF and back ON The power meter will restart running the new firmware Press the SETUP ENTER key and then Softkeys...

Page 14: ...10 Start Up Guide This page is intentionally left blank...

Page 15: ...y re certification To obtain information regarding factory service contact Newport Corporation s Service Department or your Newport representative Please have the following information available Instr...

Page 16: ...53 Aidu Road Bld 3 Flr 3 Sec C Shanghai 200131 China Telephone 86 21 5046 2300 Fax 86 21 5046 2323 Return Procedure If there are any defects in material or workmanship or a failure to meet specificati...

Page 17: ......

Page 18: ...Visit Newport Online at www newport com Newport Corporation Worldwide Headquarters 1791 Deere Avenue Irvine CA 92606 In U S 800 222 6440 Tel 949 863 3144 Fax 949 253 1680 Internet sales newport com...

Reviews: