3.2 TECHNICAL SPECIFICATIONS

3. PRODUCT OVERVIEW

CONTINUED ON NEXT PAGE

Serial number format Home Basic Edition 7
Serial number format Home Basic Edition 11

Maximum charge capacity

Standard configured charge capacity

Electric safety category

Connector type

Dimensions (H x W x D)

Weight

Standard colours

IEC-62262 IK code (robustness)

IEC-60529 IP code (protection class)

Certificates

User interface

Identification & start charging

Configuration

Backoffice protocol

Stand-by consumption

06A _ _ _ _ _ _
06B _ _ _ _ _ _

Home Basic Edition 7: single phase 32A*  (7,4kW)
Home Basic Edition 11: triple phase 16A* (11 kW)

Home Basic Edition 7: 3,7 kW - single phase 16A** 
Home Basic Edition 11: 11 kW - triple phase 16A** 

Class I

Type 2S - socket with shutter

503.5 x 200 x 137 mm

± 4.0 kg

Rear side RAL 7031 (grey)
Front side RAL 9010 (white)

IK10

IP54*** (for indoor and outdoor use)

IEC-61851-1
IEC-61851-22
EV-Ready 1.4G1 & ZE-Ready 1.4G1
IEC-62262 -> IK10
IEC-60529 -> IP54

LED

Plug & Charge

2x Rotary swiches
2x DIP switches

None

3-5W

Summary of Contents for Home Advanced Edition 7

Page 1: ...100 cm Home Basic Edition 7 Home Basic Edition 11 VERSION 06A0RNM20ENG05 2020 INSTRUCTION MANUAL EN...

Page 2: ......

Page 3: ...arth terminal for protection purposes The AC input clamps must be fitted with an uninterruptible earth for protection purposes Ensure that the connection cables are fitted with fuses and circuit break...

Page 4: ...is not connected to a back office No online services or remote support are available for this charge point In case of an error or issue on site support is needed from a ZE Ready certified installer Y...

Page 5: ...ule only for 11 kW model Cable mount clips For EV and ZE Ready installation Cable 5 x 1 5mm2 minimum for shunt and ON OFF peak accessories For EV Ready installation Shunt options ABB S2C A2 in combina...

Page 6: ...protection class Certificates User interface Identification start charging Configuration Backoffice protocol Stand by consumption 06A _ _ _ _ _ _ 06B _ _ _ _ _ _ Home Basic Edition 7 single phase 32A...

Page 7: ...lled outdoors with a road proximity less then 5 meters 3 2 TECHNICAL SPECIFICATIONS CONTINUED 3 PRODUCT OVERVIEW P1 DONGLE SPECIFICATIONS 11 KW MODEL ONLY Operating temperature range Operating humidit...

Page 8: ...EIDING P8 VERSION 0129NM02INT01 INSTRUCTION MANUAL P8 P8 06A0RNM20ENG05 3 3 OVERVIEW OF PRODUCT 3 PRODUCT OVERVIEW Type 2S shutter EV Plug socket Cover lid Identification label with serial number LED...

Page 9: ...2INT01 INSTRUCTION MANUAL P9 P9 06A0RNM20ENG05 3 PRODUCT OVERVIEW 3 4 1 OVERVIEW OF CONNECTIONS 7 4 KW VERSION Neutral wire connection Phase wire connection Earth wire connection Power cable Cable cla...

Page 10: ...CTION MANUAL P10 P10 06A0RNM20ENG05 Tension relief data cable 3 PRODUCT OVERVIEW 3 4 2 OVERVIEW OF CONNECTIONS 11 KW VERSION Phase 1 Phase 2 Phase 3 Power cable inlet Cable clamp Earth Earthing pole N...

Page 11: ...cable 11 kW model CAT5 6 UTP cable 5 wires 1 5mm2 minimum accessories cable inlet Shunt connection L1 N from accessories cable ON OFF Peak connection L2 L3 from accessories cable 11 kW model RJ12 P1 p...

Page 12: ...charge point can also be connected to 1 phase In this case the charge point can only charge on 1 phase The electrician must select a suitable MCB with C characteristic to match the amperage setting of...

Page 13: ...Overview of Connections 7 4 kW Version or 3 4 2 Overview of Connections 11 kW Version section 5 4A LOAD SHEDDING CT FOR 7 4 KW MODEL The Current Transformer for Load Shedding included in box must be c...

Page 14: ...LED will indicate whether the connection is correct If the P1 LED does not show any signal please check if the RJ12 connectors are properly connected using a network cable tester If the led of the P1...

Page 15: ...5 Volts and should be connected to the 5V pin left on the module The middle pin is not used Step 9 Plug the power adapter into a power outlet The Power LED C must light up Step 10 Consult with the cu...

Page 16: ...ABLE LOCK If the installation requires a tethered cable solution the permanent cable lock feature can be enabled Move the righter dip switch underneath the rotary switches downwards to enable the perm...

Page 17: ...ak When the switch to On peak occurs while the car is charging the charge session will be delayed until another Off peak 7 USER MANUAL TROUBLESHOOTER 7 3 TROUBLESHOOTER DO YOU SEE A RED LED LIGHT ON Y...

Page 18: ......

Reviews: