background image

5

PREPARING FOR OPERATION

1.  Check the heater for possible shipping damage. If any is found, immediately notify the factory. 

2.  Follow all of the "Precautions".

3. 

Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut 

counterclockwise into the propane cylinder's valve outlet and securely tighten with a wrench.

4. 

Connect the hose to the heater by rotating the hose fitting clockwise.

5.  Securely tighten all gas connections with a wrench.

6.  Open the cylinder's gas valve and check all gas connections with a soap and water solution. DO NOT USE 

A FLAME.

7.  Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of power.

8. 

When using an extension cord, make certain that it is a 3-wire (grounded) cord of proper wire size.

START

1. 

Before heater ignition, always allow heater fan (blower) to run for 20 seconds to purge fuel.

2.  Slowly open the main valve at propane cylinder.

3. 

Rotate the valve control knob to the “LOW/IGN” position then depress the knob to release the fuel.

4.  After the heater lights, keep the valve control knob depressed for 15 seconds then release and the heater 

will continue to operate.

5.  Adjust burn rate by setting control knob to desired level.

6. 

Igniter continues to fire as long as power cord is plugged in.

STOP

1.  Securely close valve on the propane cylinder.

2.  Continue to operate heater until all fuel in the hose has burned.

3.  Unplug the power cord.

RESTART AFTER SAFETY SHUTDOWN

1.  Securely close valve at propane cylinder. Unplug heater.

2.  Wait 5 minutes.

3.  Restart following "Start" procedure.

MAINTENANCE AND STORAGE

1. 

The heater should be inspected before each use, and at least annually by a qualified person.

2. 

Before each use, check the soft “0” ring seal at the bullnose of the POL fitting. If the “0” ring is cut, scuffed, 

or otherwise damaged, replace it.

3. 

Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.

4. 

When the heater is to be stored indoors, the connection between the LP-gas supply cylinder(s) and the 

heater must be disconnected and the cylinder(s) removed from the heater and stored out of doors and in 

accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/

NFPA 58 and CSA B 149.1, Natural Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When 

the heater is working properly:

• 

The flame is contained within the heater.

• 

The flame is essentially blue with perhaps some yellow tipping.

•  There is no strong disagreeable odor, eye burning or other physical discomfort.

• 

There is no smoke or soot internal or external to the heater.

• 

There are no unplanned or unexplained shut downs of the heater.

The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different 

from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) 

supplied with the heater.

IMPORTANT: Match the color stripe on the hang tag attached to the hose assembly with the color on the label 

located near the propane inlet fitting on the heater. Do not use alternates. For this heater, the regulator must be 

set as shown in “Specifications”. If there is any uncertainty about the regulator setting, have it checked.

A heater which is not working right must be repaired, but only by a trained, experienced service person. In 

warranty products will be repaired with no charge for either parts or Iabor. Please Include a brief statement 

indicating date, place of purchase, the nature of the problem and proof of purchase. Out of warranty products 

will be repaired with a charge for parts and labor.

Operating Instructions

Summary of Contents for NMLP120

Page 1: ...n from the area in which it is used Adequate combustion and ventilation air must be provided Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light appliance Extinguish any open flame Shut off ...

Page 2: ...V 60Hz 120V 60Hz Manifold Pressure 11 W C 11 W C 28 W C OPERATING PRECAUTIONS This is a propane direct fired convection heater It s intended use is primarily temporary heating of buildings under construction alteration or repair Propane is heavier than air If propane leaks from a connection or fitting it sinks to the floor collecting there with the surrounding air forming a potentially explosive m...

Page 3: ...ectrical power specified The electrical connection and grounding must comply with National Electrical Code ANSI NFPA 70 USA and CSA C22 1 Canadian Electrical Code Part 1 Canada 15 Use only a properly grounded 3 prong receptacle or extension cord 16 Do not move handle or service while hot or burning 17 Do not adjust the heater combustion tube elevation while heater is running or hot Adjustments to ...

Page 4: ... can smell the odorant in these fuel gases Learn to recognize the odor of propane LP gas and natural gas Local propane LP gas dealers will be more than happy to give you a scratch and sniff pamphlet Use it to become familiar with the fuel gas odor Smoking can decrease your ability to smell Being around an odor for a period of time can affect your sensitivity to that particular odor Odors present i...

Page 5: ...f the 0 ring is cut scuffed or otherwise damaged replace it 3 Turn off the gas at the LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supply cylinder s and the heater must be disconnected and the cylinder s removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage a...

Page 6: ...art 1 Select the lowest air temperature expected at the bottom of the chart 2 Move straight up to time of operation desired left side of chart 3 Read the cylinder size required NMLP60 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 60 40 20 20 9kg CYLINDER 40 18kg CYLINDER 0 20 16 4 4 6 7 18 29 DURATION OF OPERATION ON MAX HOURS AIR TEMPERATURE F C NMLP120 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 60 40 ...

Page 7: ...7 Wiring Diagrams If any original wiring as supplied with the heater must be replaced It must be replaced with Type AWG 105 C wire or its equivalent except as indicated Type SF 2 200 SGI 250 C ...

Page 8: ...8 Electronic Control Module 1 6 892974 Variable Control Knob 1 7 892975 Height Adjustment knob 2 8 892976 Hose Reg Assy 1 In order to maintain warranty components must be replaced using original manufacturers parts purchased through your dealer or directly from NewmacPro by calling 1 800 750 2723 Use of third party components will void the warranty ...

Page 9: ..._______________________________ Telephone No ______________________________________ Unit Inspected Check Gas Lines For Wear Or Leaks Check Integrity Of Orifice And Gas Ports Items Replaced ____________________________________ License No ________________________________________ Service 02 Date ________________________ Engineer Name _____________________________________ Company ______________________...

Page 10: ...rly installed maintained and operated in accordance with the instructions provided herein Furthermore United States Stove Company requires reasonable proof of the date of purchase from an authorized retailer or distributor This Limited Warranty does not cover any operational failures or difficulties due to normal use and wear and tear accident abuse misuse alteration misapplication improper instal...

Page 11: ... Company requiert une preuve raisonnable de la date d achat effectuée auprès du fournisseur ou du distributeur autorisé Cette garantie limitée ne couvre pas les échecs ou les difficultés opérationnelles dus à un usage régulier et à l usure aux accidents aux abus à l abus aux altérations à l installation ou à l entretien incorrects effectués par vous ou par une troisième partie Un échec d effectuer...

Page 12: ...one ____________________________________ Unité inspectée Vérifiez les conduites de gaz afin de déceler la présence d usure ou de fuites Vérifier l intégrité des orifices et des ports de gaz Articles remplacés _________________________________ Numéro de licence __________________________________ Service 05 Date ________________________ Nom de l ingénieur __________________________________ Entreprise __...

Page 13: ...lectronique 1 6 892974 Bouton de commande variable 1 7 892975 Bouton de réglage de la hauteur 2 8 892976 Assemblage du tuyau et du régulateur 1 Afin de conserver la garantie les composants doivent être remplacés à l aide des pièces d origine du fabricant achetées auprès de votre revendeur ou directement auprès de NewmacPro en appelant le 1 800 750 2723 L utilisation de composantes provenant de tie...

Page 14: ... avec un fil de Type AWG 105 C ou équivalent sauf sur indication contraire Type SF 2 200 SGI 250 C Blanc Noir Noir Blanc Vert Noir Blanc Bleu Bleu Bleu Jaune Terre Bleu INTERRUPTEUR THERMIQUE MOTEUR TERRE COQUILLE EXTERNE PCB RELAIS TERRE COQUILLE EXTERNE MODULE D ALLUMAGE VANNE DE CONTRÔLE CÂBLE D ALIMENTATION Aciculé d allumage ...

Page 15: ...le tube à combustion à la position souhaitée TAILLE ET CAPACITÉ DES BOUTEILLES DE PROPANE REQUISES Les tableaux ci dessous indiquent la taille approximative de la bouteille requise pour ces radiateurs Pour utiliser le tableau 1 Sélectionnez la température d air la plus basse prévue en bas du tableau 2 Déplacez vous vers le haut vers la durée de fonctionnement souhaitée côté gauche du tableau 3 Lir...

Page 16: ...chez le radiateur 2 Attendez 5 minutes 3 Redémarrez en suivant la procédure Démarrer ENTRETIEN ET ENTREPOSAGE 1 Cet appareil de chauffage devrait être inspecté avant chaque utilisation et au moins une fois par année par un technicien qualifié 2 Assurez vous de vérifier le joint torique au musoir du raccord POL avant chaque utilisation Si le joint torique est coupé rayé ou endommagé remplacez le im...

Page 17: ...uté au gaz propane liquide GPL ou au gaz naturel Vous devez déterminer votre capacité à sentir la substance odorante dans ces gaz combustibles Apprenez à reconnaître l odeur du gaz propane liquide GPL et du gaz naturel Les détaillants de gaz propane liquide GPL locaux se réjouiront de vous donner un pamphlet grattez et sentez Utilisez le pour vous familiariser avec l odeur du gaz combustible Fumer...

Page 18: ... boucher l entrée ou la sortie 14 Utilisez uniquement l alimentation électrique indiquée La connexion électrique et la mise à la terre doivent respecter le Code National Électrique ANSI NFPA 70 É U et CSA C22 1 Code Électrique Canadien Partie 1 Canada 15 Utilisez uniquement un réceptacle mis à la terre à trois 3 broches ou une rallonge 16 Ne pas déplacer manipuler ou effectuer le service de l unit...

Page 19: ... Entrée électrique 120V 60Hz 120V 60Hz 120V 60Hz Pression d admission 11 po W C 11 po W C 28 po W C PRÉCAUTIONS D UTILISATION Il s agit d un radiateur à convection à chauffage direct et alimenté au propane Ce produit est principalement conçu pour être utilisé pour un chauffage temporaire des bâtiments en construction en période de modification ou en réparation Le propane est plus lourd que l air S...

Page 20: ...ns lequel il est placé Une bonne combustion et une bonne ventilation de l air doivent être fournies Ne stockez pas ou n utilisez pas d essence ou d autres vapeurs et liquides inflammables à proximité de cet appareil ou de tout autre appareil Une bouteille de GPL non raccordée ne doit pas être entreposée à proximité de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS DÉCELEZ UNE ODEUR DE GA...

Reviews: