Tea POD Holder:
Insert the Tea POD Holder ~ with a "Tea POD" into the brew chamber. Place a cup or
measuring container on the cup stand minimum size of 10 ounces. Push the
Classic
button calibrate tea
pod holder Insert the tea pod holder
with a tea pod in place
into the brew chamber. At this point, the
Tea POD Holder will run 45 seconds delivering water into the cup placed on the cup stand. Once this
cycle is finished, remove the cup and measure the amount of water. Next, input the "Measured Amount"
of water by pushing the
Mild
(Left Arrow) or
Dark
(Right Arrow) button to the measured volume. Push the
Classic
(Done) button and the calibration process is finished for the Tea POD Holder. Next prompt will be
the
Faucet
Calibration.
Tea Pod
(
?
) (CAL) (
?
) (X)
7. Press the “
Classic
” button and the calibra-
tion is complete. Prompting to “
Faucet
”
calibration
Press Calibrate
Amount = 11oz
(-) (Done) (+) (X)
Press to finish
-
+
2. Insert Tea Pod Holder
with a tea pod in place
into Brew chamber
Tea Pod Calibration:
Measure Volume of water
3. Place 10oz cup or measuring con-
tainer on cup stand
Calibrating: = 0:45
Press any button to abort
Amount = 8oz
(-) (Done) (+) (X)
Scroll up or down to set the measured volume.
6. Input measured amount by Pressing the
“
Mild
” or “
Dark
” buttons
4. Push the “
Classic
” button. Water will run for
:45 seconds into the cup
5. Measure Volume of water in fluid ounces
1. Press “
Classic
” button to calibrate
7