background image

                                                            #803172 Issued 3-29-13 Rev. 012015      

11 

DIAL REMOVAL 

 

Use 1.5mm hex wrench to remove dial knob. This wrench is supplied with 
the unit. IMPORTANT: When removing the dial knob note the position of 
the white indicator on the knob. Remove the dial plate after the dial knob is 
removed. This area is now open for cleaning and troubleshooting. 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

When reassembling dial knob to shaft be sure that the white indicator is in 
the same position as before. If factory orientation is lost turn the bare dial 
knob shaft clockwise until it stops and position the dial as shown above. 
Tighten setscrew. 

 

1.5 mm Hex Wrench #803201 

3mm x 5mm Setscrew #803200 

Dial Knob #803118 

Dial 
Plate

 

White 

Indicator 

Summary of Contents for 872DS

Page 1: ...OR USE WITH BAG IN BOX The Post Mix Beverage Series utilizes a venturi valve to mix the syrup with the water 3650 New Town Blvd St Charles MO 63301 www newcocoffee com 636 925 1202 800 325 7867 MODEL...

Page 2: ...fitting on rear of the dispenser Fitting may vary 4 Turn on the water source to the dispenser 5 Turn the yellow knob to the ON position to allow water to flow through the urn Product Loading 1 Open th...

Page 3: ...it or when changing product Flush should be performed at least once a week Note Cleaning requires the use of a cleaning flush adapter An adapter may be purchased from Newco Enterprises Inc 320282 for...

Page 4: ...sanitizer manufactures instructions Use 100 F water 7 Place BIB connector into the sanitizing solution Ensure connector is submerged to bottom 8 Place a large vessel under the faucet Lock or hold fauc...

Page 5: ...t forget to clean sanitize faucet seat cup 7 Do follow all cleaning and sanitizing pro cedures remove and store concentrate if urn will not be used for an extended period of time ie more than two days...

Page 6: ...product 1 Concentrate BIB empty 2 Product hose clogged 3 Product hose kinked 4 Check valve not seating 5 Adjustment screw in too far 1 Load new BIB 2 Clean product hose or replace 3 Check for kinks 4...

Page 7: ...e Calibration For Post Mix Beverage Dispenser Remove Top Cover Remove Product And Hang Over Sides Of Dispenser Loosen Screw Slide Access Panel Toward Front And Remove After Access Panel Is Removed Adj...

Page 8: ...xture Make small adjustments approximately 1 points or 1 8 turn at a time Replace Access Panel and Tighten Screw Replace Product Syrup Lines Top Cover To Adjust Flow Rate Rotate Adjustment Screw Clock...

Page 9: ...Part No 803172 Issued 3 29 13 Rev 012015 9...

Page 10: ...Part No 803172 Issued 3 29 13 Rev 012015 10...

Page 11: ...al plate after the dial knob is removed This area is now open for cleaning and troubleshooting When reassembling dial knob to shaft be sure that the white indicator is in the same position as before I...

Reviews: