background image

 

PowerSwap Nucleus MINI System

 Owner's Manual  | 

 

3

Storage and Disposal

Operating Guidelines

Storage and Disposal

Storage Instructions: 

•  DO nOT SHOrT TerMInAlS.

•  This battery should be stored in a cool, dry, and well-ventilated area.  Sustained elevated tempera-

tures are the primary reason for premature failure of batteries.  Charge batteries at room tempera-

ture. In warm climates, keep chargers in air conditioned rooms for best performance.

•  Although our batteries have good self-discharge characteristics, batteries should be stored for long 

term storage in a fully charged condition.

•  It is always a good idea to submit the battery to a discharge/charge cycle from time to time during 

storage.

•  Do not store batteries in temperatures above 140

o

 F/60

o

 C or below -40

o

 F/-20

o

 C. Do not store in 

direct sunlight or near heating equipment.

Disposal Instructions: 

•  DO nOT InCInerATe. DO nOT DISASSeMBle.

•  Disposal must be in compliance with applicable regulations which vary depending on national, state/

provincial and local basis. This battery contains recyclable materials so recycling is strongly recom-

mended.

PowerDock MINI Operating Instructions

Step 2:

 Place fully charged batter-

ies in PowerDock MInI Station. 

Make 

sure battery is fully engaged and 

the LED lights on the battery are lit

*Batteries should be inserted firmly, 

but never slammed into place.

Step 3:

 Turn PowerDock MInI 

Station on (-) (switch located 

as shown). leD should light 

green.

When unit is not in use, turn the PowerDock MINI OFF. Batteries will continue to drain if unit is left on.

Tip: Monitor battery status with the leD meter on battery. When batteries become low, alarm will sound 

and battery should be swapped with a fully charged one.

Step 1:

 Confirm your device(s) is 

plugged into the AC outlet(s).

Summary of Contents for PowerSwap Nucleus MINI

Page 1: ...Powered Process Improvement 73 Ward Hill Ave l Haverhill MA l 01835 l USA l 1 781 935 3450 l www newcastlesys com PowerSwap Nucleus MINI System Owner s Manual...

Page 2: ...TECHNICAL SUPPORT 1 781 935 3450 EXT 3 ii PowerSwap Nucleus MINI System Owner s Manual Document Number PowerSwap_Nucleus_MINI_00_B Revision Date March 9 2020 Release Date November 2019...

Page 3: ...ess information or other pecuniary loss arising out of the use of this documentation even if Newcastle Systems Inc has been made aware of the possibility of such damages Information contained in this...

Page 4: ...ines Storage and Disposal 3 PowerDock MINI Operating Instructions 3 PowerCharge MINI Operating Instructions 4 Fuel Gauge 5 Preventative Maintenance Maintenance 6 Inspection 6 Service Warnings Service...

Page 5: ...e PowerDock MINI and Power Charge MINI Do not attempt to use a charger or DC load not manufactured by Newcastle Systems Inc with this product Special precautions and handling instructions are containe...

Page 6: ...em Owner s Manual 1 Cart Configurations System Components Cart Configurations PowerDock MINI Station may be mounted to the following cart configurations EC Series Cart Laptop Series Cart coming soon Y...

Page 7: ...owerDock MINI Station PWD1M This may be installed on a Newcastle cart See Cart Configura tions on page 1 to view your cart configuration 2 PowerCharge MINI Station PWC1M This is used to charge PSNU1 8...

Page 8: ...store in direct sunlight or near heating equipment Disposal Instructions DO NOT INCINERATE DO NOT DISASSEMBLE Disposal must be in compliance with applicable regulations which vary depending on nationa...

Page 9: ...teries should be inserted firmly but never slammed into place Step 3 Confirm LED changes color from green to orange during charge Note LED will turn green once fully charged Charging time of the PWC1...

Page 10: ...anual 5 Fuel Gauge Fuel Gauge The following graphics illustrate the amount of battery power and corresponding LED lighting sequence Illustration of Fuel Gauge LEDs Battery Fuel 5 81 100 4 61 80 3 41 6...

Page 11: ...ting caused by dirt or disengaging connectors under load One badly pitted contact particularly in a connector attached to a battery charger can lead to pitting on surfaces of other contacts If not cor...

Page 12: ...to extreme high above 140o F 60o C or low below 32o F 0o C temperatures This includes storage in direct sunlight in cars in hot or cold weather or in close proximity to heating cooling devices This m...

Page 13: ...of damage to electric plug and cord pull by plug rather than cord when discon necting anything from the unit 5 The use of an extension cord is not recom mended If an extension cord is used make sure t...

Page 14: ...please contact your local authorities or dealer and ask for the correct method of disposal ENVIRONMENTAL HAZARD Contains Lithium Ion Disposal DO NOT dispose of the Nucleus components and its associat...

Page 15: ...rating Capacity 18 Ah Chemistry Lithium Iron Phosphate LiFePO4 Maximum Discharge Rate 12 0 A Cut off Charge Current 2000 mA Typical Run Time Assuming Constant Load 10W 20 hrs 26W 8 hrs 41W 5 hrs 69W 3...

Page 16: ...NI Specifications PWC1M Power Input 120 VAC 60 Hz 3 A Output 10 A DC Charge Time 3 hrs Operating Transportation and Storage Environment Temperature Range 32 to 104o F 0 to 40o C Relative Humidity 20 7...

Page 17: ...Regulation Transportation Regulation Transportation Regulation Requirements for shipping Lithium Ion batteries in the US are located in 49CFR173 185 Please refer to local state and or Federal regulat...

Page 18: ...73 Ward Hill Ave l Haverhill MA l 01835 l USA l 1 781 935 3450 l www newcastlesys com...