Installation
22
SA3-SInstallation&CommissioningManual
6
Installation
The SA3-S can be installed either at the overspeed governor or near the control system. Ideally, installation is
such that the display can be seen. The remote display module is then not necessary.
201,7
171,9
189,0
80,0
100,1
121,2
55,3
Ø 5,2
Ø 6,8
X1
X2
Figure 4: SA3-S dimensions in mm
On the bottom of the housing, an additional approx. 100mm are needed for plugs and cable outlet. The left plug
(X1) is the connection to the overspeed governor (position sensor, solenoid and readback contact). The right
plug (X2) contains the connection to the control system. Both the safety circuit as well as the 24V control signals
are transmitted here. Outside of the plug, two or three separate lines are used for safety circuit and control
signals.
Connection to the overspeed governor:
The connection to the overspeed governor is pre-assembled by the Jungblut company (order option: cable
length).
Connection to the control system:
The connection to the control system is pre-assembled by the Jungblut company (order option: cable length).
The connection to the control system consists of two or three separate cables for the safety circuit and the 24V
control signals.
Cable assignments correspond to tables 2 and 3 from chapter 5.