![New lift SA3-S Installation & Commissioning Manual Download Page 25](http://html1.mh-extra.com/html/new-lift/sa3-s/sa3-s_installation-and-commissioning-manual_1677994025.webp)
Interfaces
SA3-SInstallation&CommissioningManual
21
5.5
RemoteDisplayModule
In cases where the SA3-S has to be mounted in an inaccessible location where direct operation of the unit or
reading of the display is not possible, the SA3-Remote Display Module can be used to provide remote control
and monitoring of the SA3-S. The Remote Display Module is designed to be mounted on a DIN-rail in the con-
trol cabinet. It duplicates the SA3-S‘s built-in display and additionally provides a door-zone indicator and a error
reset switch.
34,0
77,0
Figure 3: Dimensions Remote Display Module in mm
5.5.1 UserInterfaces
Double digit 7-segment LED display.
The 7-sement LED display duplicates the SA3-S‘s built-in display. The Remote Display Module will show „--“
(„minus,minus“) whenever it does is not receiving valid data.
Yellow LED (door zone)
The yellow LED indicaes that the car is currently inside the door -zone. When either of the two door-zone
signals of the SA3-S are closed, the LED is illuminated, otherwise it is turned off.
Green LED (communications link)
The Green LED indicates that data is being received by the Remote Display Module via the RS485 lines.
Red Button (SA3-S reset)
The red button can be used to reset a SA3-S error. The reset procedure is the same as when using a separately
hard wired reset switch.
Electrical connections:
Terminal Description
SA3-S-terminal Function
1
B485
B4
RS485 data line (negative)
2
A485
B8
RS485 data line (positive)
3
Reset
A7
resetting the output of errors
4
+24V
A1
power supply (24V ±10%, 40mA)
5
GND
A5
reference potential
Table 7: Electrical connections Remote Display Module