Safety
Applicable standards and guidelines
Manual TFT Position indicators
7
2
Safety
The position indicator may only be operated in perfect working condition in a proper manner, safely
and in compliance with the manual, the valid accident prevention regulations and the guidelines of the
local power company.
The safety guidelines of the FST manual and the FST Installation and Commissioning manual apply
for this product.
2.1
Applicable standards and guidelines
›
DIN EN 81; Part 1 and 2:
Safety guidelines for the construction and installation of passenger and goods passenger lifts
›
DIN VDE 0100:
Conditions for the erection of high voltage installations with nominal voltages up to 1 kV
›
VDE 0106
Contact protection measures in the machine room.
›
ZH 1/312 - BGI 779
Data sheet on safety measures for the installation, maintenance and repairs of lift systems
›
EN 12015:2012
Electromagnetic compatibility – Product family standard for lifts, escalators and moving walkways –
Emitted interference
›
EN 12016:2011
Electromagnetic compatibility – Product family standard for lifts, escalators and moving walkways –
Interference immunity
2.2
Handling electronic assemblies
Electrostatic charging
›
Keep the electronic assembly in its original packaging until installation to prevent damage.
›
Before opening the original packaging, a static discharge must be performed!
To do this, touch a grounded piece of metal.
›
During work on electronic assemblies, periodically repeat this discharge procedure!
›
Equip all bus inputs/outputs not in use with a terminal resistor (terminator) to prevent malfunctions.