Technical data
Pin assignment
14
Manual TFT Position indicators
3.3.3 I/O pin settings
The I/O pins can be set a) via the LON Module Center or b) via the FST.
For further information, please contact the NEW
LIFT
service line!
3.3.4 Emergency functions
Please wait / Please speak
At the inputs
Please Wait
and
Please speak
, the respective signals can be fed from the emergency call
unit to the TFT. As soon as the inputs are switched, the corresponding event is triggered.
The
Please speak
signal takes precedence over the
Please wait
signal.
›
The following applies for the onboard design:
The display is permanently programmed. There is a larger status bar containing the
Please wait
or
Please speak
icon.
›
The following applies for the custom design:
The events can be configured individually.
Emergency lighting
›
The emergency lighting function is an auxiliary luminous panel which is activated in the event of a fault.
›
The emergency lighting can be actuated via the bus.
›
The emergency lighting is detected if:
»
the bus voltage drops (the HSG supply is essential in the case of this condition) or
»
if the FSM reports a car lighting fault.