16
hour position blinking display , press “
”or “
”to modify hour value ,press “
” to confirm and “1 ”
、
“OFF ”symbols blinking display .the minute position blinking display ,press “
”or “
”to modify minute
value ,then press “
” to confirm then enter hour setting ,the hour position blinking display , press “
”or
“
”to modify hour value ,press “
”to confirm and enter “2 unit timing startup ”
,
its operation same as
above .
1.3.9.3 Exit timing setting :in timing setting status ,press “
” or in 20s without any key operations then quit
current timing setting and exit timing setting status .
1.3.9.4 Cancel timing setting; after enter timing setting status, long press “
” for 3 secs to cancel the
configured timing function.
1.3.10 Memory function :in shutdown status ,long press “
” for 3 secs,the LCD display “POSET”then enter
memory function setting ,press “
”or “
”to set value as “on” or “off ”;If value is “on ”,the wired contact
memory setting status before powering off .if value is “off ”wired controller memory shutdown status .
1.3.11 Backlight setting ; in shutdown status ,long press “
” for 3 secs, the LCD display “LCD SET” then
enter backlight setting ,press “
”or “
”to adjust the brightness. Press any keys except “
”or “
”
to save setting or if no any keys operation in 5s the controller will save current setting and exit.
1.3.12 Running parameters list:
No.
Status name
Units
Indication
range
Remarks
d01
DC inverter compressor current actual frequency
Hz
0
~
150
d02
DC inverter compressor run (input )current
A
0
~
30.0
d03
exhaust gas temperature
℃
-15
~
999
d04
return gas temperature
℃
-30
~
999
d05
evaporator coil temperature
℃
-30
~
999
d06
outdoor am temperature
℃
-30
~
999
d07
inlet water temperature
℃
-15
~
999
d08
outlet water temperature
℃
-15
~
999
d09
Electronic expansion value pulse step count
P
0
~
500
pulse step count
d10
DC-link voltage
V
0
~
500
d11
module temperature
℃
-15
~
999