New Age Hi-Laser Beta LASER Manual Download Page 14

Rev. 00 of 12.06.09 

14/18 

red; if the operator is adjusting the bar power, then the device limits the duty 
cycle value showing it as red. 

NOTE:

 

if the intensity set or its regulation cause excessive heating or pain in 

the treated zone, the intensity of the stimulation must be reduced immediately 
or the application must be stopped

 

5 . 3

 

–   P o s t u r e   t o   b e   k e p t   d u r i n g   t h e   s e s s i o n s  

 

The ideal posture is to be relaxed, lying on ones back or facedown depending 
on the zone of application. This position must be maintained during the entire 
session  to  facilitate  the  effects  produced  by  the  laser  beam,  especially  the 
increased  the  blood  flow  due  to  dilation  of  the  blood  vessels,    During 
treatment,  the  knob  must  maintain  a  perpendicular  position  to  the  treated 
area. 
– POWER SUPPLY 
 

ß LASER

 must be powered by the electrical mains – Precautions for use 

 

(1)

 

Do not short-circuit the terminals. 

(2)

 

Do not set off sparks or flames. 

 
 

Ca p.6

 

–   S YM B OL S 

 

    BF DEVICE 

 

 

 

ATTENTION, CONSULT THE ATTACHED DOCUMENTATION 

 

THIS DEVICE IS MARKED CE IN COMPLIANCE WITH  

0476     

DIRECTIVE EEC 93/42. 

  

   DO NOT DISPOSE OF IN COMMON WASTE 

Summary of Contents for Hi-Laser Beta LASER

Page 1: ...ax 39 0545 369028 Web www newageitalia it E mail info newageitalia it This document is property of New Age Italia srl All rights are reserved Any copy or reproduction of it through any means including...

Page 2: ...Rev 00 of 14 01 10 2 24...

Page 3: ...mulation 10 2 4 Setting time and intensity of emission 10 2 5 Interrupt end therapy 10 2 6 Turning device off 10 2 7 Configuration 10 Cap 3 PRE SET PROGRAMS 11 Cap 4 FREE PROGRAMS 12 4 1 Setting a new...

Page 4: ...7 9 4 Other features 17 Cap 10 BASIC SUPPLY AND ACCESSORIES 18 10 1 Basic supply 18 10 2 Accessories and consumption material 18 ATTENTION READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE IT IS RECOM...

Page 5: ...lable its experience in the physiotherapy field through the various programs that each appliance owns this enables the operator to be operational and efficient right from the first applications obtain...

Page 6: ...rocirculation One of the effects deriving from using the high power LASER is the distinct vasoactive effect on the microcirculation The activation of the microcirculation entails greater oxygenation a...

Page 7: ...rthritis arthritis arthrosis sciatica lumbago General traumatology articular sprains tendonitis tenosynovitis muscle strains bruises bursitis enthesitis torn muscles pathologies of overload muscular i...

Page 8: ...Cap 2 OPERATION NOTE check the contraindications and follow indications carefully before applying LASER therapy 2 Knob push button 6 Stop button 1 Touch screen display 3 safety key 4 Optical fibre ou...

Page 9: ...erned parameters are type of emitted wave supplied power therapy duration duty cycle of the generated wave 2 2 2 Reset program mode Press START on the initial screen touch screen to access the work ar...

Page 10: ...PRESS THE KNOB repeatedly to pass from the intensity parameter to the time parameter and vice versa The minimum density increase is of 1 and the maximum settable intensity is 100 the minimum time incr...

Page 11: ...ogies which can benefit from the effects of electromagnetic fields chronic pathologies articular problems oedemas etc This chapter lists the programs pre set inside the device LASER has 30 different p...

Page 12: ...phase Press PARAMETERS on touch screen to move the cursor in the work phase setting section In this zone ROTATE THE KNOB to set the parameter value and PRESS THE KNOB to pass from one parameter to an...

Page 13: ...changed during the program to increase its affects It can also be decreased in case of overheating or if pain is felt The device is endowed with a special function that allows to have safer treatment...

Page 14: ...k or facedown depending on the zone of application This position must be maintained during the entire session to facilitate the effects produced by the laser beam especially the increased the blood fl...

Page 15: ...r or other parts are damaged broken or missing it appears that the features of the device have been changed for safety purposes do not operate with accessories e g knobs and power supply other than th...

Page 16: ...rature between 5 and 40 C and less than 80 humidity The same conditions must be maintained during transportation and storage In case of malfunctioning and failures do not use the device but send it to...

Page 17: ...standards EN 60601 1 1 2003 Collateral safety standard EN 60601 1 2 2003 Collateral standard Electromagnetic compatibility Provisions and tests EN 60601 1 4 1997 Collateral standard Programmable elect...

Page 18: ...e goggles for the patient N 1 knob 1 power cable 1 User manual N 1 Trolley 1 0 2 A c c e s s o r i e s a n d c o n s u m p t i o n m a t e r i a l The following is the list of accessories which can be...