Neuvition Lidar User Manual
The threaded hole of the mounting base should reach a depth of more than 5mm to ensure
firm locking.
When the Lidar is installed at a low height, the installation position should ensure that the
scanning field of view is not blocked by other objects. (The installation height at least 0.6 meters
to 1.5 meters.)
It’s recommended that the fixed platform be as flat as possible, without unevenness, and
Aluminum alloy material is selected as the fixed platform to facilitate the heat dissipation of the
Lidar.
4.Network configuration
4.1 Overview
Titan M1 Lidar adopts standard Ethernet interface for input and output, and the factory default
static IP address is 192.168.1.101.
4.2 Ubuntu direct connection configuration
(1) Right-click the network icon in the upper right corner of the screen and select Edit
Connection, or open the network in system settings , select wired in the pop-up dialog box ,
and click the option button in the lower right corner.
Figure 7 Ubuntu network window
(2) Find Ethernet column in the pop-up network connection window, users can choose to add
or edit the existing Ethernet connection.