![network GYDA-SC Product Manual Download Page 6](http://html1.mh-extra.com/html/network/gyda-sc/gyda-sc_product-manual_1675366006.webp)
GYDA-SC
Rev.
4
2
Specifications
2.1
System
Type: Intel
80486
compatible.
CPU: 100MHz.
Memory: 32MB
Operating system:
Linux ver. 2.2.x.
2.2
Ethernet Port
Type:
10BaseT, IEEE802.3, half duplex.
Connector:
RJ-45, 100 W, UTP cable, EIA/TIA category 3 or better.
2.3
Web interface
-
HTTP version 1.1, HTML ver 4.01 Compatible with all major browsers.
2.4
SNMP interface
-
SNMP ver 1.0 over UDP over IP, following SMI version 2.0 according to relevant
RFC’s.
-
User defined community string.
-
User defined traps.
2.5
TCP/IP stack
Version: V4.
Static IP address selection: Yes, by editing a configuration file on the compact flash
card.
2.6
Serial ports
-
1 x RS422 or RS485 internal to the flashlink frame, available on the power supply
backplane.
-
1 x RS422/RS485 to external equipment. (Not in use).
-
1 x RS232 to external equipment. Service use only.
2.7
Number of cards monitored
-
79 flashlink
®
cards maximum.
2.8
GPI inputs
Number of inputs:
4.
Pull-up resistors:
Internal 4.7kOhm resistor connected to +5V.
Trigger voltage:
2.5V
±
0.5V.
2.9
GPI outputs
Number of outputs:
1.
6