background image

DA-AA  

 

 

 

Rev. 5

 

DATE: 24 July 2008 

 

 

 

 

 

                                                   

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 
E-mail: [email protected] – Web: http://www.network-electronics.com/ 
 
Technical specifications are subject to be changed without notice. 

 

 

15

Materials declaration and recycling information 

Materials declaration 

For product sold into China after 1st March 2007, we comply with the “Administrative Measure on the 
Control of Pollution by Electronic Information Products”.  In the first stage of this legislation, content of 
six hazardous materials has to be declared.  The table below shows the required information. 

Toxic or hazardous substances and elements 

 

組成名稱

 

Part Name 

 

Lead 

(Pb) 

 

Mercury 

(Hg) 

 

Cadmium

(Cd) 

六价铬

 

Hexavalent 

Chromium

(Cr(VI)) 

多溴联苯

 

Polybrominated 

biphenyls  

(PBB) 

多溴二苯醚

 

Polybrominated 

diphenyl ethers

(PBDE) 

 DA-AA 

O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for 
this part is below the limit requirement in SJ/T11363-2006. 
 
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous 
materials used for this part is above the limit requirement in SJ/T11363-2006. 

 

Environmentally-friendly use period  

The manual must include a statement of the “environmentally friendly use period”.  This is defined as the 
period of normal use before any hazardous material is released to the environment.  The guidance on how 
the EFUP is to be calculated is not finalised at the time of writing.  See 

http://www.aeanet.org/GovernmentAffairs/qfLeOpAaZXaMxqGjSFbEidSdPNtpT.pdf

 for an unofficial 

translation of the draft guidance. For our own products, Network Electronics has chosen to use the 

50 

year figure

 recommended in this draft regulation.  

Network Electronics suggests the following statement on An “Environmentally Friendly Use Period” 
(EFUP) setting out normal use:  

EFUP is the time the product can be used in normal service life without leaking the hazardous materials.  We expect the normal 
use environment to be in an equipment room at controlled temperature range (0ºC - 40ºC) with moderate humidity (< 90%, non-
condensing) and clean air, not subject to vibration or shock.   

Further, a statement on any hazardous material content, for instance, for a product that uses some tin/lead 
solders: 

Where a product contains potentially hazardous materials, this is indicated on the product by the appropriate symbol containing 
the EFUP.  The hazardous material content is limited to lead (Pb) in some solders.  This is extremely stable in normal use and the 
EFUP is taken as 50 years, by comparison with the EFUP given for Digital Exchange/Switching Platform in equipment in 
Appendix A of “General Rule of Environment-Friendly Use Period of Electronic Information Products”.  This is indicated by the 
product marking: 

Summary of Contents for Flashlink DA-AA

Page 1: ...network electronics com Analogue Audio Distribution Amplifier Rev 5 Flashlink User Manual DA AA...

Page 2: ...available in pdf format on our web site http www network electronics com Current revision of this document is the uppermost in the table below Revision Replaces Date Change Description 5 4 2008 01 31...

Page 3: ...TPUT CONFIGURATION 8 Configuration of ANA1 output 8 Configuration of ANA2 outputs 8 4 Connector module 10 4 1 Mounting the connector module 11 5 Module status 11 5 1 Front Panel Status Monitoring 12 6...

Page 4: ...ier The latter configuration is made by connecting the inputs in parallel or using DIP switch on PCB The Distribution amplifier has differential inputs and differential outputs Overall gain can be set...

Page 5: ...el 25 dBu Output voltage balance ratio 30dB Output common mode rejection 50dB Switched gain tolerance 0 1dB Gain 12 to 12 dB Features High quality audio distribution Configurable dual 1x4 or single 1x...

Page 6: ...b http www network electronics com Technical specifications are subject to be changed without notice 6 3 Configuration setup The DA AA has two channels ANA1 and ANA2 DIP switch 1 ANA1 and 2 ANA2 sets...

Page 7: ...mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 7 1 8 Don t Care On Off 600 ohms load on outputs 10kohms loa...

Page 8: ...ually configured using DIP switch 3 and DIP switch 4 The switch sets which of the input that is connected to the output Configuration of ANA1 output Use dip switch SW4 ANA1 for setting the outputs ANA...

Page 9: ...AS P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be ch...

Page 10: ...NA1 output 4 ANA1 output 4 ANA2 output 1 ANA2 output 1 ANA2 output 2 ANA2 output 2 ANA2 output 3 ANA2 output 3 ANA2 output 4 ANA2 output 4 Figure 6 Overview of the ADC AES C1 connector module The DA A...

Page 11: ...Analogue Audio ANA2 positive output 2 4 Analogue Audio ANA2 negative output 2 17 Analogue Audio ANA2 positive output 3 15 Analogue Audio ANA2 negative output 3 3 Analogue Audio ANA2 positive output 4...

Page 12: ...DA AA has 2 LEDs each showing a status corresponding Diode state Red LED Yellow LED Green LED No light Status Module is faulty Module is OK Module power is OK Module has no power Input No signal pres...

Page 13: ...t notice 13 General environmental requirements for Network flashlink equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating...

Page 14: ...Web http www network electronics com Technical specifications are subject to be changed without notice 14 Product Warranty The warranty terms and conditions for the product s covered by this manual fo...

Page 15: ...This is defined as the period of normal use before any hazardous material is released to the environment The guidance on how the EFUP is to be calculated is not finalised at the time of writing See h...

Page 16: ...supported for 50 years Recycling information Network Electronics provides assistance to customers and recyclers through our web site http www network electronics com Please contact Network Electronic...

Page 17: ...ble DA AA MODEL NUMBER S Analogue Audio Distribution Amplifier DESCRIPTION LVD 73 23 EEC EMC 2004 108 EEC DIRECTIVES this equipment complies with EN 55103 1 1996 EN 55103 2 1996 HARMONISED STANDARDS a...

Reviews: