J6:
Function Pin
Analogue Audio ANA1 positive output 1
24
Analogue Audio ANA1 negative output 1
12
Analogue Audio ANA1 positive output 2
10
Analogue Audio ANA1 negative output 2
23
Analogue Audio ANA1 positive output 3
21
Analogue Audio ANA1 negative output 3
9
Analogue Audio ANA1 positive output 4
7
Analogue Audio ANA1 negative output 4
20
Analogue Audio ANA2 positive output 1
18
Analogue Audio ANA2 negative output 1
6
Analogue Audio ANA2 positive output 2
4
Analogue Audio ANA2 negative output 2
17
Analogue Audio ANA2 positive output 3
15
Analogue Audio ANA2 negative output 3
3
Analogue Audio ANA2 positive output 4
1
Analogue Audio ANA2 negative output 4
14
Ground
2, 5, 8, 11,16,19,22,26
4.1 Mounting the connector module.
The details of how the connector module is mounted, is found in the user manual for the sub-rack frame
FR-2RU-10-2.
This manual is also available from our web site: http://www.network-electronics.com/
5. Module status
The status of the module can be monitored in three ways.
1. GYDA System Controller (optional).
2. LEDs at the front of the sub-rack.
LED’s are mounted on the module itself, whereas the GYDA System Controller is a separate module
giving detailed information on the card status. The function of the LEDs are described in sections 5.1.