DA-AA
Rev. 5
DATE: 24 July 2008
Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
12
5.1 Front Panel - Status Monitoring
The status of the module can be easily monitored visually by the LED’s at the front of the module. The
LED’s are visible through the front panel. The LED on top tells if the DA-AA is ok or not (green LED
means ok – red is alarm). The second LED gives the input signal status.
The DA-AA has 2 LEDs each showing a status corresponding.
Diode \ state
Red LED
Yellow LED
Green LED
No light
Status
Module is faulty
Module is OK
Module power is OK
Module has no
power
Input
No signal present
Signal present
6. Interface with GYDA and RS-422 command set
All commands follow the flashlink protocol and can be used for direct control access to the modul. The
control system can either be a GYDA-SC or a third-party control system with integrated flashlink
protocol. The module can also be manually controlled with a VT100 compatible terminal program.
The protocol can be found on our web page; http://www.network-electronics.com
6.1 DA-AA Command table
Command Response
Comment
?
See protocol description
The
“hello”
command
Info
Module status information
Status
Give module status