background image

 

                                                                                                  i                                                                      

Man073  Rev. 1/24/06                

 
 

TRADEMARK 

XTENDEX is a trademark of Network Technologies Inc in the U.S. and other countries.     

 

COPYRIGHT 

Copyright © 2006 by Network Technologies Inc.  All rights reserved.  No part of this publication may be reproduced, stored in a 
retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, 
without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202. 

 

CHANGES 

The material in this guide is for information only and is subject to change without notice.  Network Technologies Inc reserves the 
right to make changes in the product design without reservation and without notification to its users. 
 
 
 
 
 

Note: Shielded CAT 5,5e, or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission 
requirements

 

Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products 
should not be run underground, outdoors or between buildings.       

 
 
 
 

                     

WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty. 

 

!

Summary of Contents for XTENDEX ST-C5VA-WL500

Page 1: ...500 WALL MOUNT VGA VIDEO AND STEREO AUDIO EXTENDER Installation and Operation Manual XTENDEXTM Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202...

Page 2: ...rora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product design wit...

Page 3: ...8 Video Quality 9 Technical Specifications 9 Interconnection Cable Wiring Method 10 Troubleshooting 10 Warranty Information 11 TABLE OF FIGURES Figure 1 Install Local Unit to 2 gang outlet box 4 Figu...

Page 4: ...eet see page 8 for more details Compatible with all NTI switches and splitters enabling the joining of products to create a system that satisfies all networking needs Video quality adjustment for vary...

Page 5: ...when there is communication between the Local and Remote Units 10 Green LED power indicator illuminates when power has been supplied to the Remote Unit supplied through the CAT5 cable 11 Audio Jack 3...

Page 6: ...the video signal i e AC motors welding equipment etc All cables should be installed in such a way that they do not cause stress on their connections to the equipment Extended lengths of cable hanging...

Page 7: ...Connect the CAT5 cable to the Local Unit When properly inserted the cable end should snap into place WARNING Never connect the XTENDEX to an Ethernet card Ethernet router hub or switch or other Ethern...

Page 8: ...ck marked line out The line out jack is typically lime green and may be marked with this symbol The spkr jack is typically orange and may be marked with this symbol The headphones jack may be marked w...

Page 9: ...he local speakers to the 3 5mm stereo audio jack labeled AUDIO OUT on the Local Unit Figure 3 Connect the local user to the XTENDEX Local Unit VIDEO AUDIO OUT IN IN OUT AUDIO VIDEO NTI R www nti1 com...

Page 10: ...ach reach the Remote Unit without putting strain on the cables Figure 4 Attach wall mount brackets to Remote Unit Connect Monitor and Speakers 1 Position the Remote Unit such that the CAT5 cable the m...

Page 11: ...5 connector of an Ethernet device Damage to devices connected to the Ethernet may result Figure 6 Connect the CAT5 cable to the Remote Unit Plug in and Power Up 1 Plug the power cord from the monitors...

Page 12: ...rs 3 5mm stereo jack to CPU Signal Type Line Level stereo unbalanced Audio Frequency Response 20Hz to 20Khz 2dB Signal to noise ratio 73 dBA Total Harmonic Distortion and Noise 0 011 Stereo Crosstalk...

Page 13: ...are experienced while installing this product please look over the troubleshooting chart below for answers any questions that might arise If the answer is not found in the chart please check the FAQs...

Page 14: ...round The CAT5 cable is not properly connected Make sure the interconnection cable is not near any power lines Check cable connections Make sure they are snapped in properly and completely Image is no...

Reviews: