background image

 

 
 

 

 

 

T3232-140/155M / T6464-140/155M 

T9696-140/155M / T128128-140/155M 

T3232-140/155S / T6464-140/155S 

 

VikinX

®

 Modular 140/155 Mbps Telecom 

Router 

 
 
 
 
 
 
 
 
 
 
 
 

Hardware Manual 

 
 
 
 

Rev. 4 

 
 

Summary of Contents for VikinX T128128-140

Page 1: ...T3232 140 155M T6464 140 155M T9696 140 155M T128128 140 155M T3232 140 155S T6464 140 155S VikinX Modular 140 155 Mbps Telecom Router Hardware Manual Rev 4...

Page 2: ...9 Revision history Current revision of this document is the uppermost in the table below Revision Replaces Date Change description 4 3 2007 03 30 Added Materials Declaration and EFUP updated EC Declar...

Page 3: ...o configure the router and modules 14 3 3 Power Supply module 15 3 3 1 Module insertion 15 3 3 2 Module removal 15 3 3 3 How to connect power to the Modular Telecom Router 15 3 3 4 Status LEDs and Rel...

Page 4: ...Connecting signal cables to the Modular Telecom Router 27 6 Before calling Network Support 28 7 Serial number overview 29 Notes 30 Materials Declaration and EFUP 31 Materials declaration 31 Environmen...

Page 5: ...eed performance specification under the following environmental conditions Operating room temperature range 0 C to 45 C Operating relative humidity range 95 non condensing 2 The equipment will operate...

Page 6: ...ty The warranty terms and conditions for the Modular Telecom Router follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Network Ele...

Page 7: ...es The source code for these components and our modifications are available from http labs network electronics com open source You may also send Network Electronics a recordable CD and a self addresse...

Page 8: ...rear panel VikinX Modular provides all important 3 rd party control interfaces allowing the control of our routers through 3 rd party management software On top of that does the Network Electronics TH...

Page 9: ...ule DC Supply voltage range 36 72VDC 300W DC Mains connector Screw terminal separate input for each PSU module Alarms Power failure alarm on relay contact closure LED in front and Open Collector to GY...

Page 10: ...bps Connector 75 ohm BNC female Impedance 75 ohm nominal Return loss 15dB 5 540Mhz Cable equalisation 0 to 300m typical Belden 8281 Electrical signal outputs Connector 75 ohm BNC female Impedance 75 o...

Page 11: ...Modular Telecom Router Rev 4 Timing adj range 0 20 lines in 1 line steps 11...

Page 12: ...SU is installed screw terminals not mounted on illustrated router above Serial A1 and A2 RS 232 or RS 422 for external control protocols Serial B1 and B2 RS 232 or RS 422 for external control protocol...

Page 13: ...Synchronisation signal 1 in out Blackburst composite tri level sync reference input with passive loop through for vertical interval switching VIT 2 Synchronisation signal 2 in out Blackburst composit...

Page 14: ...he door may be removed for easy access to the modules An important feature of all the modules in the Modular Telecom Router frame is that they are all hot swappable The user does not have to turn off...

Page 15: ...supply module one must insert the module via the special plastic guide rails into its position Once the module is inserted fix the module by lifting up the handle on the front and pushing it to the u...

Page 16: ...r supply module that selects mains voltage The mains voltage can be either 110VAC or 230VAC This switch must be set in the correct position depending on the mains voltage on the router s site Failing...

Page 17: ...card fails and install this CF card on a new SysCon card The router will not notice the difference 3 4 1 Card insertion The frame is equipped with plastic guide rails to align the SysCon cards into th...

Page 18: ...ase the card by moving the red handle until it is in horizontal position as shown in the figure below Then pull the card out of the sub rack with the red handle 3 4 3 Status LEDs and Reset button Ther...

Page 19: ...nd software reconfigurations upgrades Medium load on the Controller Low or normal load on the Controller Not applicable Reset button The reset button on the rear side is used to perform a hard reset o...

Page 20: ...e description earlier in this manual 2 Slide the battery out of its socket and insert the new battery into the socket 3 Insert the SysCon card into its slot according to the description earlier in thi...

Page 21: ...me as on the SysCon card See Chapter 3 4 3 3 5 4 CF card and battery The Compact Flash CF card and battery are both inserted and or removed in the exact same way as on the SysCon card See Chapter 3 4...

Page 22: ...the card The tip of the handles enters the hole and the card is locked and proper contact ensured when you hear a click from both handles Note that it may be necessary to press hard when inserting th...

Page 23: ...on the card is outside their legal range All internal voltages are OK TEMP The temperature of the card is outside its legal range The temperature of the card is OK FAN1 Fan error when the fan speed is...

Page 24: ...Modular Telecom Router Rev 4 switch must always be in the position towards the card front The switch is for factory use only Reset button Service switches SW4 SW2 24...

Page 25: ...routers are as follows Bit rate 19200 bit s Data bits 8 bits Stop bits 1 Parity No parity For further detail concerning this protocol please refer to the following manual VikinX Compact Protocol pdf T...

Page 26: ...onnection 4 3 Ethernet connection The connections follow the standard set by the IEEE 802 3 100BaseTX specification The cables that are to be applied should be CAT 5 CAT 5E standard or better It is th...

Page 27: ...elecom Router Rev 4 5 Connecting signal cables to the Modular Telecom Router The Modular Telecom Router offers standard 75Ohms BNC connectors for in and outputs All inputs are terminated with 75Ohms P...

Page 28: ...Warn LED on the SysCon card is RED An abnormal situation has occurred See Chapter 2 If the router has redundant PSU modules check that both modules are properly installed and are working If the route...

Page 29: ...when contacting Network Electronics ASA for product support Device Part Part Serial number Frame including all static cards Power Supply Module 1 Power Supply Module 2 if included X point Card 1 X poi...

Page 30: ...Modular Telecom Router Rev 4 Notes 30...

Page 31: ...s substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 Parts without any of the above mentioned hazardous substances are...

Page 32: ...b site http www network electronics com Please contact Network Electronics ASA s Customer Support for assistance with recycling if this site does not show the information you require Where it is not p...

Page 33: ...EEC DIRECTIVES this equipment complies with EN 55103 1 1996 EN 55103 2 1996 EN 60950 1 2006 HARMONISED STANDARDS applied in order to verify compliance with Directive s TEST REPORTS ISSUED BY Notified...

Reviews: