6
The related Attribute ID of Electrical Measurement Cluster ID:
Current Attribute ID: 0x0508
Voltage Attribute ID: 0x0505
Power Attribute ID: 0x050B
Power Factor Attribute ID: 0x0510
The command to reset power consumption summation: 0xE0. The format is:
Bits:8
16
8
8
8
Frame
control
Manufacturer
code
Transaction
Sequence
number
Command
identifer
Frame payload
Action
0x05
0x109F
0xe0
0x00
(clusterid
:
0x0702
,
Action
:
0x00)
5-8. Report Configuration for Developer Only
After the device receives ConfiugreReport (Max! = 0xFFFF) command, if the configuration is successful, it will
immediately issue a Report command and then it will report according to report setting.
After powering on, Z809A will detect battery voltage, if the device report has been previously configured, it will
issue 1 or 2 reports within 1-60 seconds randomly on the device, and thereafter it will report according to the
configuration.
Report setting table
:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable
Change
Change rate≥ Reportable
Change
Change rate
<
Reportable Change
1-65534
1-65534
≠
0
To report per Minimum
interval
To report per Maximum
interval
0
To report per Minimum
interval
To report per Minimum
interval
0
1-65534
≠
0
To report instantly
To report per Maximum
interval
0
To report per second
To report per second
1-65534
0
≠
0
To report per Minimum
interval
No report
0
To report per Minimum
interval
To report per Minimum
interval
0
0
≠
0
To report instantly
No report
0
To report per second
To report per second
Any
65535
Any
Stop reporting
65535
Any
Any
Stop reporting
Note
:
(1) It is not suggested to set:
Min Interval =0,