11
Load Protection:
The current is over 16A → it will be off-load in 2 seconds
After it is off-load, the Bit1 (Current OverLoad) of the parameter ACAlarmsMask will be checked:
Bit1 (Current OverLoad) is 1 → it sends the alarm message
Bit1 (Current OverLoad) is 0 → it doesn’t send the alarm message
When it sends the alarm message → AlarmCluster = 0x0B04; AlarmCode = 0xF0; Network Indicator flashes
10 times.
9. Important Maintenance Instructions
Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain
minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device
dry properly before storing or using.
Do not use or store the device in dusty or dirty areas.
Do not use or store the device in extremely hot temperatures. High temperatures may damage the device or
battery.
Do not use or store the device in extremely cold temperatures. When the device warms to its normal
temperature, moisture can form inside the device and damage the device or battery.
Do not drop, knock, or shake the device. Rough handling would break it.
Do not use strong chemicals or washing to clean the device.
Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep your device
operational. For damaged device, please contact the authorized service center in your area.