Yellow
Red
Green
0
0
0
Automatic mode, HEATER stopped
0
1
0
Automatic mode,
HEATER operating
1
0
0
Manual
mode OFF forced
1
1
0
Manuel
mode
HEATER forced
0
or
1
0
or
1
quick flash
Reception of an order,
4 flash
0
or
1
0
or
1
1
Waiting for a
configuration
signal (cf. configuration)
0
0
slow blink
ERROR see repair sequence bellow:
Repair instructions
- Verify the emitter batteries.
- Verify the emitter/receiver range.
- No perturbation by an apparatus at less than 50cm of
the receiver.
- No perturbation by an apparatus on the 433.92 MHz
frequency (continuous transmission).
By pressing on the push
button
nothing happens
- Verify that the receiver is correctly connected
- Verify main power supply (230VAC)
Operating temperature
0°C - 50°C (or 32°F
– 122°F)
Electrical
Protection
Class II - IP44
Power Supply
230Vac 50Hz
Radio frequency and
Receiving zone
433.92 MHz, <10mW.
Range of approximately 100m in open space.
Range of approximately 30m in residential environment.
certifications
CE. EN 300220-3,
EN 301489 (Radio frequency certifications)
Output
Relay 12A 250Vac
USER GUIDE
GB
1 channel RF Receiver 230Vac (EFHRFR 001)
MODES DESCRIPTION
-
Radio frequency RF receiver (433.92 Mhz).
-
Personal code on each product.
-
Equipped with a push
button to select
AUTO
,
MANUAL
or
RF INIT
mode.
-
To be used only with ours thermostats.
RADIO CONFIGURATION MODE
1. Install and plug the Receiver. Then press the Receiver push button during 4
seconds, the Green LED should lit up indicating that the Receiver is now in radio
configuration mode waiting for a thermostat configuration address.
2. Please refer to the thermostat leaflet for enter
the thermostat in “RF Init” mode.
3. Verify that radio signals are correctly received by the Receiver. On the Receiver,
the Green LED should blink at each radio signal received from the thermostat.
4. Exit the Radio configuration mode on the thermostat. (Please refer to the
thermostat leaflet)
5. Now starting up your installation in AUTO mode.
LED INDICATOR
Mode push button
AUTO Mode
Press
button
Manual Mode
(Heater forced)
Press
button
Manual Mode
(Stop forced)
Press
button
during 4sec
Manual Mode LED.
(Yellow)
RF LED.
(Green)
TECHNICAL CHARACTERISTICS
Press
button
RF init
Heating LED.
(Red)
Press
button
PPL IMP 2107B