background image

 

 

Cluster ID for Z307 

Server side 

Client side 

EP 0x01 (Device ID: IAS Zone(0x0402) ) 

Basic(0x0000) 

None 

power configure(0x0001) 

 

Identify(0x0003) 

 

Commissioning(0x0015) 

 

Poll Control(0x0020) 

 

IAS zone ( 0x0500) 

 

Diagnostics Information(0x0B05) 

 

 

1

Attributes of the Basic Information   

Identifier 

Name 

Type 

Range 

Access 

Default 

Mandatory 

/ Optional 

0x0000 

ZCLVersion 

Unsigned 

8-bit integer 

0x00 – 

0xff 

Read only 

0x03 

0x0001 

ApplicationVersion 

Unsigned 

8-bit integer 

0x00 – 

0xff 

Read only 

0x0002 

StackVersion 

Unsigned 

8-bit integer 

0x00 – 

0xff 

Read only 

53 

0x0003 

HWVersion 

Unsigned 

8-bit integer 

0x00 – 

0xff 

Read only 

20 

0x0004 

ManufacturerName 

Character 

string 

0 – 32 

bytes 

Read only 

netvox 

0x0005 

ModelIdentifier 

Character 

string 

0 – 32 

bytes 

Read only 

Z307E3ED 

0x0006 

DateCode 

Character 

string 

0 – 16 

bytes 

Read only 

0x0007 

PowerSource 

8-bit 

Enumeration 

0x00 – 

0xff 

Read only 

0x03 

0x0010 

LocationDescription 

Character 

string 

0 – 16 

bytes 

Read/write 

 

0x0011 

PhysicalEnvironment 

8-bit  

Enumeration 

0x00 – 

0xff 

Read/write 

0x00 

0x0012 

DeviceEnabled 

Boolean 

0x00 – 

0x01 

Read/write 

0x01 

Summary of Contents for Z307

Page 1: ...Z307 WirelessTM Wireless Fall Sensor Wireless Rechargeable Fall Sensor User Manual Software V4 0 Hardware V1 2...

Page 2: ...Automatic Zone Registration enrollment 4 4 4 Emergency and Position System 4 4 5 Turn on Permit join Function 5 4 6 Activate the Device 5 4 7 Low power Notification 5 4 8 Restore to Factory Setting 5...

Page 3: ...This CIE would then instruct other devices in the network to sound or silent alarm with light strobe Z307 acts as an end device in the network which does not perform permit join other devices to join...

Page 4: ...d and release the button the device will vibrate once to enter the OFF state Note Power off Z307 when not in use is recommended 4 2 Join to the Network In order for the Z307 to communicate with the Zi...

Page 5: ...the event of emergency the user may press the emergency button once the device vibrates once while it sends alarm signal to the security system for strobe light or siren alert Fall Detect When the wea...

Page 6: ...roadcast its own short address and IEEE address Z307 will stay active for 2 minutes Note turn on interval after powering on is 5 min by default setting 4 7 Low power Notification The operating voltage...

Page 7: ...d to normal operating status To prevent this unwanted power consumption we recommend that users manually power off the device 4 10 Battery Charging The device is built in 3 7V lithium rechargeable bat...

Page 8: ...rance 5 ZigBee Description 1 End Point s 0x01 2 Device ID IAS Zone 0x0402 3 Cluster ID which EndPoint supports Status indicator red Network indicator green A201 Infrared sensor A201Charging indicator...

Page 9: ...bit integer 0x00 0xff Read only O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 53 O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xff Read only 20 O 0x0004 ManufacturerName Characte...

Page 10: ...information Click the icon to enter the state of Figure 5 2 Fig 5 1 Fig 5 2 2 Click the red box in Figure 5 2 above the settings section configure whether to open the alarm sound Click to enter the c...

Page 11: ...10 3 When an alarm occurs the warning message shown in FIG 5 5 Fig 5 5 7 Related Devices A201 Wireless Charger A201 Infrared sensor A201Charging indicator DC power input 5V...

Page 12: ...and causing the housing to deform Do not use or store the device in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that i...

Reviews: