4.5 Turn on Permit-join Function 

   

After the device joins the network, you can press  shortly  the  “Binding  key”  to enable the coordinator in the 

network and the allowed function of all routing devices, allowing time is set  to be 60 seconds. If it needs to be 

turned off immediately, it only needs to be short again within 60 seconds, press the “Binding key”.   
 

4.6 Activate the Device 

 

 

The device is battery powered and is designed to enter sleep mode when not transmitting. Sometimes you would 

need to collect attribute data during the installation and during the deployment process, you need to force the 

device to enter active mode. 

Operation:   

Hold press the binding key and emergency button together until the red light flashes twice then release the key. 

 

The device should automatically broadcast its own short address and IEEE address. Z307 will stay active for 2 

minutes. 

 

Note: turn on interval after powering on is 5 min by default setting.   

4.7 Low power Notification 

The operating voltage of Z307 is between 3.2 to 4.2VDC. 

When the battery is bellow operating voltage 3.2V, the  red  indicator on Z307 will flash once.  The device will 

broadcast low power notification to the network and also sends this battery status to the enrolled CIE device. 

 

 

4.8 Restore to Factory Setting

 

Z307 is capable of storing and saving includes network information. If you wish to remove Z307 from an exited 

network, you would need to clear the information and restore to the factory setting; or if you wish to join Z307 to a 

new network, a restore to factory default is required. 

 

Operation: 

Step 1. Press and hold both binding key and setting key for 5 seconds till the red indicator flashes quickly and the 

releases.   

Step 2. Red indicator flashes 20 time to restore the device to factory setting.   

 

 

 

 

Summary of Contents for Z307

Page 1: ...Z307 WirelessTM Wireless Fall Sensor Wireless Rechargeable Fall Sensor User Manual Software V4 0 Hardware V1 2...

Page 2: ...Automatic Zone Registration enrollment 4 4 4 Emergency and Position System 4 4 5 Turn on Permit join Function 5 4 6 Activate the Device 5 4 7 Low power Notification 5 4 8 Restore to Factory Setting 5...

Page 3: ...This CIE would then instruct other devices in the network to sound or silent alarm with light strobe Z307 acts as an end device in the network which does not perform permit join other devices to join...

Page 4: ...d and release the button the device will vibrate once to enter the OFF state Note Power off Z307 when not in use is recommended 4 2 Join to the Network In order for the Z307 to communicate with the Zi...

Page 5: ...the event of emergency the user may press the emergency button once the device vibrates once while it sends alarm signal to the security system for strobe light or siren alert Fall Detect When the wea...

Page 6: ...roadcast its own short address and IEEE address Z307 will stay active for 2 minutes Note turn on interval after powering on is 5 min by default setting 4 7 Low power Notification The operating voltage...

Page 7: ...d to normal operating status To prevent this unwanted power consumption we recommend that users manually power off the device 4 10 Battery Charging The device is built in 3 7V lithium rechargeable bat...

Page 8: ...rance 5 ZigBee Description 1 End Point s 0x01 2 Device ID IAS Zone 0x0402 3 Cluster ID which EndPoint supports Status indicator red Network indicator green A201 Infrared sensor A201Charging indicator...

Page 9: ...bit integer 0x00 0xff Read only O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 53 O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xff Read only 20 O 0x0004 ManufacturerName Characte...

Page 10: ...information Click the icon to enter the state of Figure 5 2 Fig 5 1 Fig 5 2 2 Click the red box in Figure 5 2 above the settings section configure whether to open the alarm sound Click to enter the c...

Page 11: ...10 3 When an alarm occurs the warning message shown in FIG 5 5 Fig 5 5 7 Related Devices A201 Wireless Charger A201 Infrared sensor A201Charging indicator DC power input 5V...

Page 12: ...and causing the housing to deform Do not use or store the device in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that i...

Reviews: