background image

 

 

Example for MinTime/MaxTime logic:   

 

Example#1

 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. 

BatteryVoltageChange=0.1V

 

 

 

 

                                         

MaxTime                                                                                          MaxTime

 

 

 

 

                                 

 

Sleeping(MinTime)       

                                                                               

  Sleeping(MinTime)   

 

       

 

 

 

 

 

 

 

Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration 
regardless BatteryVoltageChange value.   
 
 

Example#2

 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. 

BatteryVoltageChange= 0.1V.

 

                                                                       

 

MaxTime

 

 

 

 

 

Sleeping(MinTime)             

   

  sleeping                          sleeping   

   

                sleeping 

 

 

0H

                                  15

th

  M                              30

th

  M                        45

th

  M                             

1H

                         

2H 

               

 

 

 

 

 

Example#3 

based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. 

BatteryVoltageChange= 0.1V. 

                                                                                                                                                                                                             

MaxTime 

 

 

Wakes up and 

collects data 

3.6V   

Does not report   

Wakes up and 

collects data 

3.6V 

Does not report 

Wakes up and 

collects data 

3.6V 

Does not report   

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and 

collects data 

REPORT 3.6V 

Wakes up and collects data 

3.5V |3.5-3.6|=0.1 

REPORTS 3.5V 

Wakes up and 

collects data 3.5V 

Does not report 

Wake up and collects data 

REPORTS 3.6V 

Wakes up and collects data 

REPORTS 3.6V   

Wakes up and collects data 

REPORTS 3.6V 

Users push the button, 

REPORTS 3.5V. 

Recalculate MaxTime. 

Summary of Contents for R718PG

Page 1: ...s document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in...

Page 2: ...able of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 10 8 Important Maintenance Instruction...

Page 3: ...spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building auto...

Page 4: ...can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery life Battery...

Page 5: ...joined the network Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setti...

Page 6: ...uplink packet including illuminance and battery voltage The device sends data in the default configuration before any configuration is done Default setting MaxTime Max Interval 15 min 900s MinTime Min...

Page 7: ...tRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte...

Page 8: ...sleeping 0H 15th M 30th M 45th M 1H 2H Example 3 based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Wakes up and collects data 3 6V Does not report Wake...

Page 9: ...than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up freq...

Page 10: ...ollowing scenarios Family School Storage room Hospital Bar Stairs Agricultural greenhouse To detect the illumination value 1 Light Sensor R718PG has a built in magnet see Figure 1 below When installed...

Page 11: ...tery passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from...

Page 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...