5
Low Voltage Warning
Low Voltage
3.2V
5. Data Report
Data report configuration and sending period are as following:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number
between 1~65535
Any number
between 1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
The device will immediately send a version packet report along with an uplink packet including illuminance
and battery voltage.
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime : Max Interval = 15 min = 900s
MinTime : Min Interval = 15 min = 900s
BatteryChange: 0x01 (0.1V)
IlluminanceChange:0x0032 (50 Lux)
Illuminance detection range:
0 ~ 157000 Lux
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be the minimum time.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
to resolve uplink data.