Example of Report configuration

 

FPort

0x07 

Bytes 

Var(Fix =9 Bytes) 

 

CmdID  DeviceType 

NetvoxPayLoadData 

CmdID

 1 byte 

DeviceType

 1 byte 

 Device Type of Device 

NetvoxPayLoadData

 var bytes (Max=9bytes) 

 

Description 

Device 

Cmd

ID 

Device 

Type 

NetvoxPayLoadData 

Config 

ReportReq 

R718PG 

0x01 

0x1E 

MinTime 

(2bytes 

Unit:s) 

MaxTime 

(2bytes 

Unit:s) 

BatteryChange 

(1byte Unit:0.1v) 

Illuminancechange 

(4bytes Unit

1Lux) 

Config 

ReportRsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes,Fixed 0x00) 

ReadConfig 

ReportReq 

0x02 

Reserved 

(9Bytes,Fixed 0x00) 

ReadConfig 

ReportRsp 

0x82 

MinTime 

(2bytes 

Unit:s) 

MaxTime 

(2bytes 

Unit:s) 

BatteryChange 

(1byte Unit:0.1v) 

Illuminancechange 

(4bytes Unit

1Lux) 

 

(1)

 

Command Configuration:

 

  MinTime = 1min

MaxTime = 1min

BatteryChange = 0.1v

IlluminanceChange = 100 Lux 

          Downlink

011E003C003C0100000064              003C(H

ex) 

=60 (D

ec) ,

 64(H

ex) 

=100 (D

ec) 

   

          Response

 

                       

     

811E000000000000000000 

Configuration success

 

                       

   

  811E010000000000000000

Configuration failure

 

 

(2)

 

Read Configuration:

 

         

Downlink

021E000000000000000000 

          Response

 

                       

     

821E003C003C0100000064 

Current configuration

 

 

 
 

Summary of Contents for R718PG

Page 1: ...s document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in...

Page 2: ...able of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 10 8 Important Maintenance Instruction...

Page 3: ...spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building auto...

Page 4: ...can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne Improved power management for longer battery life Battery...

Page 5: ...joined the network Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setti...

Page 6: ...uplink packet including illuminance and battery voltage The device sends data in the default configuration before any configuration is done Default setting MaxTime Max Interval 15 min 900s MinTime Min...

Page 7: ...tRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte...

Page 8: ...sleeping 0H 15th M 30th M 45th M 1H 2H Example 3 based on MinTime 15 Minutes MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime Wakes up and collects data 3 6V Does not report Wake...

Page 9: ...than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up freq...

Page 10: ...ollowing scenarios Family School Storage room Hospital Bar Stairs Agricultural greenhouse To detect the illumination value 1 Light Sensor R718PG has a built in magnet see Figure 1 below When installed...

Page 11: ...tery passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from...

Page 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: