6
Example of Report configuration
FPort
:
0x07
Bytes
1
1
Var(Fix =9 Bytes)
CmdID DeviceType
NetvoxPayLoadData
CmdID
–
1 byte
DeviceType
–
1 byte
–
Device Type of Device
NetvoxPayLoadData
–
var bytes (Max=9bytes)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
R718PG
0x01
0x1E
MinTime
(2bytes
Unit:s)
MaxTime
(2bytes
Unit:s)
BatteryChange
(1byte Unit:0.1v)
Illuminancechange
(4bytes Unit
:
1Lux)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes
Unit:s)
MaxTime
(2bytes
Unit:s)
BatteryChange
(1byte Unit:0.1v)
Illuminancechange
(4bytes Unit
:
1Lux)
(1)
Command Configuration:
MinTime = 1min
、
MaxTime = 1min
、
BatteryChange = 0.1v
、
IlluminanceChange = 100 Lux
Downlink
:
011E003C003C0100000064 003C(H
ex)
=60 (D
ec) ,
64(H
ex)
=100 (D
ec)
Response
:
811E000000000000000000
(
Configuration success
)
811E010000000000000000
(
Configuration failure
)
(2)
Read Configuration:
Downlink
:
021E000000000000000000
Response
:
821E003C003C0100000064
(
Current configuration
)