7. Information about Battery Passivation 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many 

advantages including low self-discharge rate and high energy density.      

 

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium 

anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride 

layer prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation 

may also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

 

As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more 

than one month from the date of battery production, all the batteries should be activated. 

 

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

 

ER14505 Battery Passivation: 

7.1 To determine whether a battery requires activation 

Connect a new ER14505 battery to a resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation.   

 

7.2 How to activate the battery 

a. Connect a battery to a resistor in parallel   

b. Keep the connection for 5~8 minutes 

c. The voltage of the circuit should be 

3.3, indicating successful activation. 

 

Brand 

Load Resistance 

Activation Time 

Activation Current 

NHTONE 

165 Ω 

5 minutes 

20mA 

RAMWAY 

67 Ω 

8 minutes 

50mA 

EVE 

67 Ω 

8 minutes 

50mA 

SAFT 

67 Ω 

8 minutes 

50mA 

Note:   

If  you  buy  batteries  from  other  than  the  above  four  manufacturers,  then  the  battery  activation  time,  activation  current,  and 

required load resistance shall be mainly subject to the announcement of each manufacturer. 

Summary of Contents for R718J

Page 1: ...R718J Wireless Dry Contact Interface Wireless Dry Contact Interface R718J User Manual...

Page 2: ...2 3 Main Feature 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Information about Battery Passivation 8 7 1 To determine whether a battery requires activation 9 7 2 How to activate the b...

Page 3: ...dulation method greatly increases the communication distance compared with other communication methods and can be widely used in long distance low rate IoT wireless communication fields in various occ...

Page 4: ...ferromagnetic material object Protection class IP65 IP67 Optional Compatible with LoRaWANTM Class A Frequency hopping spread spectrum Configuration parameters can be configured via a third party soft...

Page 5: ...joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search...

Page 6: ...umber between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval When the device is turned on it will immediately send a version package Data will be reported once per hour by defaul...

Page 7: ...0 1v Downlink 0121003C003C0100000000 003C Hex 60 Dec Device returns 8121000000000000000000 configuration is successful 8121010000000000000000 configuration failed 2 Read device parameters Downlink 02...

Page 8: ...commend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter...

Page 9: ...ttery voltage is detected that exceeds the change value during Min Time the data will be reported immediately 4 Whether the state of the dry contact is change a piece of data will be reported regularl...

Page 10: ...rage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to elim...

Page 11: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...

Reviews: