R718J is a ClassA external dry contact device based on LoRaWAN open protocol of Netvox. It can externally connect various 

switches, buttons, relays and reed switch output. It can detect the closing or disconnecting signal of dry contact and is compatible 

with LoRaWAN protocol. 

 

LoRa wireless technology: 

LoRa is a wireless communication technology dedicated to long-distance low-power consumption. Its spread-spectrum 

modulation method greatly increases the communication distance compared with other communication methods, and can be 

widely used in long-distance low-rate IoT wireless communication fields in various occasions. Such as automatic meter reading, 

building automation equipment, wireless security systems, industrial monitoring and control. It has the characteristics of small 

size, low power consumption, long transmission distance and strong anti-interference ability. 

 

LoRaWAN: 

LoRaWAN defines an end-to-end standard specification using LoRa technology to ensure interoperability between devices and 

gateways from different vendors. 

2. Appearance 

 

 

Summary of Contents for R718J

Page 1: ...R718J Wireless Dry Contact Interface Wireless Dry Contact Interface R718J User Manual...

Page 2: ...2 3 Main Feature 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Information about Battery Passivation 8 7 1 To determine whether a battery requires activation 9 7 2 How to activate the b...

Page 3: ...dulation method greatly increases the communication distance compared with other communication methods and can be widely used in long distance low rate IoT wireless communication fields in various occ...

Page 4: ...ferromagnetic material object Protection class IP65 IP67 Optional Compatible with LoRaWANTM Class A Frequency hopping spread spectrum Configuration parameters can be configured via a third party soft...

Page 5: ...joined the network Turn on the device to search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search...

Page 6: ...umber between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval When the device is turned on it will immediately send a version package Data will be reported once per hour by defaul...

Page 7: ...0 1v Downlink 0121003C003C0100000000 003C Hex 60 Dec Device returns 8121000000000000000000 configuration is successful 8121010000000000000000 configuration failed 2 Read device parameters Downlink 02...

Page 8: ...commend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter...

Page 9: ...ttery voltage is detected that exceeds the change value during Min Time the data will be reported immediately 4 Whether the state of the dry contact is change a piece of data will be reported regularl...

Page 10: ...rage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to elim...

Page 11: ...astic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the devic...

Reviews: