6. Data Report
The device will send a version package report immediately after power-on. After it is powered on, and the auto-calibration
is executed for one minute (Do not move the device), the device will report the attribute data.
Note:
1. The device must be placed horizontally during automatic calibration.
2. After calibration, the x, y, z three-axis angles are about 0°, 0°, -90° when the device is placed horizontally.
3. There will be no operation when pressing the button before the automatic calibration is completed.
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 60 min = 3600s
MinTime: Max Interval = 60 min = 3600s (It is recommended that MinTime is not less than 1min.)
(By default, the current voltage and three-axis tilt value are detected once every Min Interval.)
Battery Change = 0x01 (0.1v)
Angle Change = 0xC8 (1°; The accuracy is 3° in horizontal position.)
Angle of Three-axis:
If the three-axis acceleration of the device exceeds ActiveThreshold, and the tilt angle variation of one of the three axes
is greater than or equal to the set AngleChange after the device is stationary, a report will be sent. After the three-axis tilt
angle and battery voltage are reported, the three-axis acceleration of the device needs to be lower than InActiveThreshold,
the duration is greater than 5s (cannot be modified), and the vibration stops completely, the next detection will start. If the
vibration continues during this process after the report is sent, the timing will restart.
Note:
(1)
The device report interval will be programmed based on the default firmware which may vary.
(2)
The interval between two reports must be the minimum time.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver